Weider Core 600 Bench English Manual - Page 10

Attach a Connector 28 to the Left Upright 11

Page 10 highlights

12. Attach a Connector (28) to the Left Upright (11) 12 with two M5 x 19mm Screws (52), two M10 x 90mm Bolts (45), and two M10 Washers (55). Do not tighten the Screws yet. Attach the other Connector (28) to the Right Upright (10) in the same way. 10 28 28 52 11 55 45 13. Note: If you have Olympic weights, use the 13 longer Olympic Extension (8) for this step; if you have standard weights, use the shorter Standard Extension (7). Attach the Olympic Extension (8) or the Standard Extension (7) to the Connector (28) on the Left Upright (11) with three M10 x 90mm Bolts (45), four M10 Washers (55), and three M10 Nylon Locknuts (42). Attach the Olympic Extension (8) or the Standard Extension (7) to the other Connector (28) in the same way. See step 12. Tighten the M5 x 19mm Screws (52). 28 45 8 55 55 42 45 42 28 7 11 14. Set a Safety Spotter (13) on a set of pegs on the Left Upright (11). Set the other Safety 14 Spotter (13) on a set of pegs on the Right 10 Upright (10). Make sure that both Safety Spotters are at the same height. 13 13 11 15. Make sure that all parts have been properly tightened. The use of the remaining parts will be explained in ADJUSTMENT, beginning on the following page. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
12. Attach a Connector (28) to the Left Upright (11)
with two M5 x 19mm Screws (52), two M10 x
90mm Bolts (45), and two M10 Washers (55).
Do not tighten the Screws yet.
Attach the other Connector (28) to the Right
Upright (10) in the same way.
13. Note: If you have Olympic weights, use the
longer Olympic Extension (8) for this step; if
you have standard weights, use the shorter
Standard Extension (7).
Attach the Olympic Extension (8) or the
Standard Extension (7) to the Connector (28)
on the Left Upright (11) with three M10 x 90mm
Bolts (45), four M10 Washers (55), and three
M10 Nylon Locknuts (42).
Attach the Olympic Extension (8) or the
Standard Extension (7) to the other
Connector (28) in the same way.
See step 12.
Tighten the M5 x 19mm Screws
(52).
15.
Make sure that all parts have been properly
tightened.
The use of the remaining parts will
be explained in ADJUSTMENT, beginning on
the following page.
12
13
45
45
45
28
28
28
55
55
55
42
42
11
10
28
7
11
8
14
13
13
11
10
14. Set a Safety Spotter (13) on a set of pegs on
the Left Upright (11). Set the other Safety
Spotter (13) on a set of pegs on the Right
Upright (10).
Make sure that both Safety
Spotters are at the same height.
52