MAINTENANCE AND TROUBLE-SHOOTING Inspect and tighten all parts of the exercise cycle regularly. Replace any worn parts immediately. The exercise cycle can be cleaned with a soft, damp cloth. Avoid spilling liquid on the console. Keep the console out of direct sunlight or the display may be damaged. Remove the batteries when storing the exercise cycle. HOW TO TIGHTEN THE CRANK If the arms of the Crank (33) become loose, they should be tightened in order to prevent excessive wear. Loosen the crank nut on the left arm of the Crank. Place the end of a standard screwdriver in one HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. In order to adjust the reed switch, the Left Side Shield (1) must be removed. Using an adjustable wrench, turn the Left 34 33 28 40 34 34 1 Slotted Crank Nut Crank Nut 4 33 of the slots in the slotted crank nut. Lightly tap the screwdriver with a hammer to turn the slotted crank nut counterclockwise until the arms are no longer loose. Do not overtighten the slotted crank nut. When the slotted crank nut is properly tightened, retighten the crank nut. BATTERY REPLACEMENT If the console does not function properly, the batteries should be replaced. To replace the batteries, see assembly step 2 on page 6. In addition, make sure that the console wire is connected to the reed switch wire. Pedal (28) clockwise and remove it from the Crank (33). Remove the two M4 x 12mm Self-tapping Screws (4) and the three M4 x 38mm Self-tapping Screws (34) from the Left Side Shield. Next, lift the Side Shield Cover (40) off the Side Shields. Grasp both Side Shields at the top and gently pull them apart. Make sure that the arm of the Crank is in the position shown in the drawing above. Carefully slide the Left Side Shield forward off the arm of the Crank and remove it. Next, locate the Reed Switch (50). Turn the Crank (33) 9 until the Magnet (51) 51 is aligned with the Reed Switch. 33 Loosen but do not remove the M4 x 50 16mm Self-tapping Screw (9). Slide the Reed Switch slightly closer to or away from the Magnet. Retighten the Screw. Turn the Crank for a moment. Repeat until the console displays cor- rect feedback. When the Reed Switch is correctly adjusted, reattach the left side shield and pedal. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

12
Inspect and tighten all parts of the exercise cycle
regularly. Replace any worn parts immediately.
The exercise cycle can be cleaned with a soft, damp
cloth. Avoid spilling liquid on the console. Keep the
console out of direct sunlight or the display may be
damaged. Remove the batteries when storing the
exercise cycle.
HOW TO TIGHTEN THE CRANK
If the arms of the Crank (33) become loose, they
should be tightened in order to prevent excessive
wear. Loosen the crank nut on the left arm of the
Crank. Place the end of a standard screwdriver in one
of the slots in the slotted crank nut. Lightly tap the
screwdriver with a hammer to turn the slotted crank
nut counterclockwise until the arms are no longer
loose.
Do not overtighten the slotted crank nut.
When the slotted crank nut is properly tightened,
retighten the crank nut.
BATTERY REPLACEMENT
If the console does not function properly, the batteries
should be replaced. To replace the batteries, see
assembly step 2 on page 6. In addition, make sure
that the console wire is connected to the reed switch
wire.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. In order to adjust the
reed switch, the Left Side Shield (1) must be
removed. Using an adjustable wrench, turn the Left
Pedal (28) clockwise and remove it from the Crank
(33). Remove the two M4 x 12mm Self-tapping
Screws (4) and the three M4 x 38mm Self-tapping
Screws (34) from the Left Side Shield. Next, lift the
Side Shield Cover (40) off the Side Shields. Grasp
both Side Shields at the top and gently pull them
apart. Make sure that the arm of the Crank is in the
position shown in the drawing above. Carefully slide
the Left Side Shield forward off the arm of the Crank
and remove it.
Next, locate the
Reed Switch (50).
Turn the Crank (33)
until the Magnet (51)
is aligned with the
Reed Switch.
Loosen but do not
remove the M4 x
16mm Self-tapping
Screw (9). Slide the
Reed Switch slightly
closer to or away
from the Magnet. Retighten the Screw. Turn the Crank
for a moment. Repeat until the console displays cor-
rect feedback. When the Reed Switch is correctly
adjusted, reattach the left side shield and pedal.
MAINTENANCE AND TROUBLE-SHOOTING
Crank Nut
Slotted Crank Nut
33
28
33
40
1
34
34
34
4
50
33
9
51