Whirlpool CEM2940TQ Installation Instructions - Page 14
Direct Wire, Four-wire electrical connection
View all Whirlpool CEM2940TQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Direct Wire Method 1. Disconnect power. A C D B A. External ground conductor screw B. Tab C. Terminal block cover D. Hold-down screw 2. Remove hold-down screw and the terminal block cover. 3. Install 3/4" conduit connector into the hole below the terminal block opening. Connect flexible metallic conduit and tighten connector screw. Install direct wire cable through the flexible Direct wire cable must match power supply (4-wire or 3-wire) and be: I Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated. I 10-gauge solid copper wire (do not use aluminum). I At least 5 ft. (1.52 m) long. A B C A. Conduit connector B. Dryer cabinet C. Connector screw metallic conduit. 4. Complete installation following instructions for your type of electrical connection: • Four-wire (recommended method) • Three-wire (if four-wire is not available) Direct Wire, Four-wire electrical connection: A to disconnect box 31/2" (89 mm) 1" (25 mm) of wires stripped of insulation B C D 5" (127 mm) Shape ends of wires into a hook. Strip 5" (127 mm) of outer covering from end of cable. Leave green or bare ground wire at 5" (127 mm). Cut 11/2" (38 mm) from 3 remaining wires. Strip insulation back 1" (25 mm). A. 3/4" conduit connector B. Neutral (white or center) C. Ground wire (green or bare) D. 10-gauge, 3 wire with ground wire in flexible metallic conduit 5. Remove the center terminal block screw. 6. Remove the appliance neutral ground wire from the external ground conductor screw. Fasten under center, silvercolored terminal block screw. 7. Connect the ground wire (green or bare) of the direct wire cable to the external ground conductor screw. Tighten screw. 8. Place the hooked end of the neutral wire (white or center) of the direct wire cable under the center screw of the terminal block (hook facing right). Squeeze hook end together. Tighten screw. 9. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten screws. 10. Insert tab of the terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw. 14 B A C F E D A. External ground conductor screw B. Appliance neutral ground wire C. Center terminal block screw D. Outer terminal block screws E. Neutral (center wire) F. Green or bare ground wire