Whirlpool LER5636PQ Installation Instructions - Page 2
Inst.maation - parts
View all Whirlpool LER5636PQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
INST.MAATIONSTRUCTIONS Check that you have everything necessary for correct installation. Proper installation is your responsibility. Flat-blade screwdriver • Level Adjustable wrench that opens to 1 in. or haxhead socket wrench (for adjusting dryer feet) #2 Phillips screwdriver Tin snips (new vent installations) • Safety glasses • Caulking gun and compound (for installing new exhaust vent) • Gloves • Wire stripper (direct wire installations) Parts supplied: Remove parts package from dryer drum. Check that all parts were included. • A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Extended Dryer Feet Kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. Install the dryer where it is protected from water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. Installation Clearances The location must be large enough to fully open the dryer door. Dryer Dimensions 4 leveling legs Parts needed: Check local codes. Check existing electrical supply and venting and see "Electrical Requirements" and "Venting Requirements" 1 2 before purchasing parts. Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the "Service or Assistance" section of your "Dryer User Instructions." Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. You will need • A location that allows for proper exhaust installation. See "Venting Requirements." • A separate 30 amp circuit. • A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements." • A sturdy floor to support the total weight (dryer and load) of 200 Ib (90.7 kg). 2 J 4 1. Small Opening Side-Swing Door 2. Large Opening Side-Swing Door 3. Wide Opening Side-Swing Door 4. Wide Opening Hamper Door * Most installations require a minimum 51/;,in. (14 cm) clearance behind the dryer for the exhaust vent with elbow, See "Venting Requirements." Minimum installation spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed. • Additional spacing should be considered for ease of installation and servicing. Additional clearances might be required for wall, door and floor moldings. Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer. For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.