Replacing the Incandescent Light Bulb Turn off the range hood and allow the light bulb to cool. 1. Disconnect power. 2. Squeeze the plastic lens cover and remove it from the hood. 3. Screw a 120V, 75W maximum, incandescent light bulb with E26 base into the socket. 4. Replace the lens cover by squeezing the cover and inserting the tabs into the slots. 5. Reconnect power. If the new light does not operate, make sure the light bulb is inserted correctly before calling service. W BK BK BK W R Y WIRING DIAGRAM R Motor Switch Off - On BK Lamp Switch Off - Low - High 1 2 Lamp Switch Operation 1 - 2 Off L 3 1 - 3 Low 1 - L High Rectifier Diode NOTE: Speed 1 not used W R Speed 1 W Common Speed 2 R BK C25 Motor Characteristics Power Supply 120 VAC Frequency 60 Hz Amperage 1.2 ±10% A Wattage Rating 73 ±10% Watts Motor Resistance White - Red 17.1 ±10% Ohms White - Black 13.6 ±10% Ohms Ground Screw L N GND SE114A 11