Ventsystemchart NOTEP: erformanocferearexhaustot eithesrideofthedryeris equivaletnotaddingoneelbowT. odeterminmeaximumexhaust lengtha,ddoneelbowtothechart. Numbeorf Typeof 90° turns vent orelbows Boxor Angled Louvered hoods hoods 0 Rigidmetal 64ft (20m) 58ft (17.7m) Flexiblemetal 36ft (11m) 28ft (8.5m) 4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent or gas line. For mobile home use Gas dryers must be securely fastened to the floor. 1 Rigidmetal 54ft (16.5m) 48ft (14.6m) Flexiblemetal 31ft (9.4m) 23ft (7m) 2 Rigidmetal 44ft (13.4m) 38ft (11.6m) Flexiblemetal 27ft (8.2m) 19ft (5.8m) Mobile home installations require a Mobile Home Installation Kit. 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) See "Tools and Parts" section for information on ordering. Flexible metal 25 ft (7.6 m) 17 ft (5.2 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4.6 m) 1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp. 3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90 ° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent. 1= Remove the red cap from the gas pipe. 2. Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all nonflared male fittings. If flexible metal tubing is used, be sure there are no kinks. A B........... A. Flared male thread B. Non-flared male thread NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON _t tape. Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. 1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. 2. Firmly grasp the body of the dryer (not the top or console panel). Gently lay the dryer on the cardboard. See illustration. 3= Examine the leveling legs. Find the diamond marking. 1 10 t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.