Whirlpool WGD6600VW Use and Care Guide - Page 8
Warnin
UPC - 883049141237
View all Whirlpool WGD6600VW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Burner Input Requirements: Elevations above 10,000 ft (3,048 m): ■ When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation. Gas Supply Pressure Testing ■ The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi. Dryer Gas Pipe ■ The gas pipe that comes out through the rear of your dryer has a 1/8" male pipe thread. 2" (51 mm) A 3/4" (19 mm) A. 3/8" NPT dryer pipe Venting Requirements WARNING Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. If using an existing vent system ■ Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. ■ Replace any plastic or metal foil vent with rigid heavy metal or flexible metal vent. ■ Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. If this is a new vent system Vent material ■ Use a heavy metal vent. Do not use plastic or metal foil vent. ■ 4" (102 mm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. 4" (102 mm) heavy metal exhaust vent DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the "Assistance or Service" section. Rigid metal vent ■ For best drying performance, rigid metal vents are recommended. ■ Rigid metal vent is recommended to avoid crushing and kinking. Flexible metal vent ■ Flexible metal vents are acceptable only if accessible for cleaning. ■ Flexible metal vent must be fully extended and supported when the dryer is in its final location. ■ Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. ■ Do not install flexible metal vent in enclosed walls, ceilings, or floors. ■ The total length of flexible metal duct shall not exceed 7 3/4 ft (2.4 m). Elbows 45° elbows provide better airflow than 90° elbows. Good Better Clamps ■ Use clamps to seal all joints. ■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint. Do not use duct tape. Clamp 8
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52