Yamaha CS-R5 CS-R5 Owners Manual [English] - Page 22

CONSOLE NETWORK OUT/IN connectors

Page 22 highlights

 USB ports Use these ports to connect a USB storage device such as a flash drive, USB mouse, or USB keyboard. MY card slots Install optional Mini-YGDAI I/O cards here to expand I/O ports.  CONSOLE NETWORK OUT/IN connectors These RJ-45 connectors allow the unit to be connected to a Console Network(*) in a ring topology via Ethernet cables (CAT5e or higher recommended). * Console Network A DSP engine is equipped with a special control surface terminal to connect to a control surface. A network created by the control surface and a DSP engine is called a "Console Network." NOTE • Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable's shield by conductive tape or comparable means. • The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ45 plugs can also be used. • Cable length can span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used. ! ERR indicators This indicator lights up or flashes red if an error occurs. In such an event, please contact your Yamaha dealer.  LINK indicators This indicator flashes or lights up, depending on the network status. Green (flashing) The unit is preparing to connect to the console network. If it continues flashing, the system is not functioning properly. If the problem persists after you take the following actions, please contact your Yamaha dealer. • Make sure that the cables are connected properly. • Make sure that the cables are securely inserted (locked in). • Turn the power to the RIVAGE PM5 system off and then on. • Change to a different cable. Green The unit is connected to the console (lit steadily) network properly.  TX/RX indicators The appropriate indicator flashes green when data is transmitted from (TX) or received at (RX) the TO ENGINE OUT/IN connectors.  LINK/ACT indicator This indicator flashes or lights up green, depending on the connection status. ? NETWORK connector This RJ-45 connector allows the unit to be connected to a computer or network device via an Ethernet cable (CAT5e or higher recommended). NOTE • Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable's shield by conductive tape or comparable means. • The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ45 plugs can also be used. • Cable length can span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.  Vent The control surface is equipped with cooling fans. These vents let warm air out from the unit. Please make sure that you do not block the vents with any object. The air intake is located on the bottom of the front panel. Caution Do not block the vents. This product has ventilation holes at the rear/under the front to prevent the internal temperature from becoming too high. Inadequate ventilation can result in overheating, possibly causing damage to the product(s), or even fire. AC IN connectors Use these sockets to connect the supplied power cords. First connect the AC power cords to this unit, and then insert the power cord plugs into AC outlets. Insert the cable plugs all the way until they lock in place securely. The supplied AC power cords feature a V-lock mechanism via a latch, which prevents the power cords from disconnecting accidentally. Caution Be sure to turn off the power to the unit before connecting or disconnecting the power cords. To disconnect each power cord, remove it while pressing the latch on the plug. [I]/[1] (Power switches A/B) Toggle between power on (I) and off (1). While the power is turned on, the POWER indicator (see  on page 13) on the top panel will light up. 22 CS-R5 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

CS-R5 Owner’s Manual
22
9
USB ports
Use these ports to connect a USB storage device such
as a flash drive, USB mouse, or USB keyboard.
)
MY card slots
Install optional Mini-YGDAI I/O cards here to
expand I/O ports.
!
CONSOLE NETWORK OUT/IN connectors
These RJ-45 connectors allow the unit to be
connected to a Console Network(*) in a ring
topology via Ethernet cables (CAT5e or higher
recommended).
* Console Network
A DSP engine is equipped with a special control surface
terminal to connect to a control surface. A network created
by the control surface and a DSP engine is called a
“Console Network.”
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable's shield by conductive tape or comparable means.
The use of Ethernet cables with Neutrik etherCON CAT5
compatible RJ-45 plugs is recommended. Standard
RJ45 plugs can also be used.
Cable length can span up to 100 meters between
devices. Maximum practical distance may vary
depending on the cable used.
@
ERR indicators
This indicator lights up or flashes red if an error
occurs.
In such an event, please contact your Yamaha dealer.
#
LINK indicators
This indicator flashes or lights up, depending on the
network status.
$
TX/RX indicators
The appropriate indicator flashes green when data is
transmitted from (TX) or received at (RX) the TO
ENGINE OUT/IN connectors.
%
LINK/ACT indicator
This indicator flashes or lights up green, depending
on the connection status.
^
NETWORK
connector
This RJ-45 connector allows the unit to be connected
to a computer or network device via an Ethernet
cable (CAT5e or higher recommended).
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable's shield by conductive tape or comparable means.
The use of Ethernet cables with Neutrik etherCON CAT5
compatible RJ-45 plugs is recommended. Standard
RJ45 plugs can also be used.
Cable length can span up to 100 meters between
devices. Maximum practical distance may vary
depending on the cable used.
&
Vent
The control surface is equipped with cooling fans.
These vents let warm air out from the unit. Please
make sure that you do not block the vents with any
object. The air intake is located on the bottom of the
front panel.
Caution
Do not block the vents. This product has ventilation holes
at the rear/under the front to prevent the internal
temperature from becoming too high. Inadequate
ventilation can result in overheating, possibly causing
damage to the product(s), or even fire.
*
AC IN connectors
Use these sockets to connect the supplied power
cords. First connect the AC power cords to this unit,
and then insert the power cord plugs into AC outlets.
Insert the cable plugs all the way until they lock in
place securely. The supplied AC power cords feature a
V-lock mechanism via a latch, which prevents the
power cords from disconnecting accidentally.
Caution
Be sure to turn off the power to the unit before connecting
or disconnecting the power cords.
To disconnect each power
cord, remove it while
pressing the latch on the
plug.
(
[I]/[
P
] (Power switches A/B)
Toggle between power on (
I
) and off (
P
).
While the power is turned on, the POWER indicator
(see
1
on page 13) on the top panel will light up.
Green
(flashing)
The unit is preparing to connect to the
console network. If it continues flashing,
the system is not functioning properly. If
the problem persists after you take the
following actions, please contact your
Yamaha dealer.
Make sure that the cables are
connected properly.
Make sure that the cables are securely
inserted (locked in).
Turn the power to the RIVAGE PM5
system off and then on.
Change to a different cable.
Green
(lit steadily)
The unit is connected to the console
network properly.