Application range, Do not use AC and DC power at the same time - portable generator

Page 19 highlights

AE01180 APPLICATION RANGE AC DC Power factor EF2400iS 1 0.8-0.95 0.4-0.75 (Efficiency 0.85) -2,000W -1,600W -680W Rated voltage 12V Rated current 8A NOTE: 9 "-" means below. 9 Application wattage indicates when each device is used by itself. 9 The overload indicator light 1 comes on when total wattage exceeds the application range. (See page 16 for more details.) cC q 9 Be sure the total load is within generator rated output otherwise generator damage will occur. 9 Do not use AC and DC power at the same time or the generator may be damaged. 760-029 NOTE: Some precision equipment is voltage sensitive and may require a more uniform voltage supply than portable generators provide. Examples include some medical equipment, personal computers, and some inverters that sense peak and RMS voltage values. Consult the precision-equipment vendor before relying on any portable generator to provide power to such equipment. - 14 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

14
AE01180
APPLICATION RANGE
AC
DC
Power factor
1
0.8
0.95
0.4
0.75
(Efficiency 0.85)
EF2400iS
2,000W
1,600W
680W
Rated voltage
12V
Rated current
8A
NOTE:
9
“–”
means below.
9
Application wattage indicates when each device is
used by itself.
9
The overload indicator light
1
comes on when
total wattage exceeds the application range. (See
page 16 for more details.)
c
C
9
Be sure the total load is within generator rated
output otherwise generator damage will occur.
9
Do not use AC and DC power at the same time
or the generator may be damaged.
NOTE:
Some precision equipment is voltage sensitive and may
require a more uniform voltage supply than portable
generators provide. Examples include some medical
equipment, personal computers, and some inverters
that sense peak and RMS voltage values. Consult the
precision-equipment vendor before relying on any
portable generator to provide power to such equipment.