Battery Charging, the generator may be damaged.
View all Yamaha EF2400iS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
2 1 AE00904 Battery Charging cC Do not use AC and DC power at the same time or the generator may be damaged. 761-086a 762-046 12v 762-047 w q 763-238a NOTE: The generator DC rated voltage is 12V. 1. Wind the battery charging lead 2 or 3 turns around the handle and plug into DC receptacle. NOTE: 9 Make connections to the battery after starting the engine. 9 Clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. Do not reverse these positions. 1 Red 2 Black 2. Start the engine. 3. Press in the DC protector and install the battery. cC 9 Be sure the battery leads are properly connected. 9 Be sure the breather hose is properly connected and is not damaged or obstructed. 9 Reduce the load to the specified generator rated output if the DC protector turns off. If it turns off again, consult a Yamaha dealer. NOTE: Press to reset the DC protector. 1 "ON" 2 "OFF" NOTE: 9 At full charge, electrolyte specific gravity is between 1.26 and 1.28. 9 Check specific gravity hourly. - 17 -