Yamaha HTR-5760 Owners Manual - Page 31

Result:wiring, Result:exit, Error, Error: E-5

Page 31 highlights

PREPARATION p 8 Use the cursor buttons to display the results. • Press u / d to display information about individual results. • Press j / i to switch between each result list. RESULT:WIRING FRONT L;;;;;;;OK ■ If an error screen appears AUTO SETUP 1 Press SELECT to display detailed information about the error. ERROR . E-5:NOISY []:Select [SELECT]:Return p )RETRY EXIT [ ]/[ ]:Up/Down [SELECT]:Enter 9 When finished, press SELECT. The RESULT:EXIT screen appears. 2 Press j / i to switch between error messages. For details about each message, see page 29. p p 10 Press u / d to select SET or CANCEL. RESULT:EXIT NO WARNING RESULT LIST . )SET CANCEL [ ]/[ ]:Up/Down [SELECT]:Enter ERROR: E-5 < NOISY > Keep SILENT [SELECT]:Return SET CANCEL To apply the auto setup (YPAO) settings. To cancel the auto setup (YPAO) without making any changes. 11 Press SELECT to set or cancel the auto setup settings. y If you are not satisfied with the result or want to manually adjust each setup parameter, use the manual setup parameters (see page 51). Notes • If E-10 appears during testing, restart the procedure from step 3. • To cancel the auto setup procedure before completion, press SET MENU. 3 When finished, press SELECT to return to the main error screen. 4 Press u / d to select RETRY or EXIT, then press SELECT. ERROR E-5:NOISY RETRY EXIT p . )RETRY EXIT [ ]/[ ]:Up/Down [SELECT]:Enter To retry the auto setup procedure. To exit auto setup. English p 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

27
English
AUTO SETUP
PREPARATION
8
Use the cursor buttons to display the results.
• Press
u
/
d
to display information about
individual results.
• Press
j
/
i
to switch between each result list.
9
When finished, press SELECT.
The RESULT:EXIT screen appears.
10
Press
u
/
d
to select SET or CANCEL.
SET
To apply the auto setup (YPAO)
settings.
CANCEL
To cancel the auto setup (YPAO)
without making any changes.
11
Press SELECT to set or cancel the auto
setup settings.
y
If you are not satisfied with the result or want to manually adjust
each setup parameter, use the manual setup parameters (see
page 51).
If E-10 appears during testing, restart the procedure from step 3.
To cancel the auto setup procedure before completion, press
SET MENU.
If an error screen appears
1
Press SELECT to display detailed
information about the error.
2
Press
j
/
i
to switch between error
messages.
For details about each message, see page 29.
3
When finished, press SELECT to return to
the main error screen.
4
Press
u
/
d
to select RETRY or EXIT, then
press SELECT.
RETRY
To retry the auto setup procedure.
EXIT
To exit auto setup.
Notes
±±±±
FRONT
±
L
;;;;;;;
OK
±±±±
[<]/[>]:Select
±±±±
[SELECT]:Return
RESULT:WIRING
RESULT:EXIT
±±NO±WARNING
±±RESULT±LIST
±±
.
±
)
SET±±±±CANCEL
±±[±]/[±]:Up/Down
±±[SELECT]:Enter
p
p
ERROR
.
±E-5:NOISY
±±
)
RETRY±±EXIT
±±[±]/[±]:Up/Down
±±[SELECT]:Enter
p
p
ERROR: E-5
±±
±±
<
±
NOISY
±
>
±±
±±
Keep
±
SILENT
±±
±±
[SELECT]:Return
ERROR
±±
±±
E-5:NOISY
.
±
)
RETRY±±
±±
EXIT
±±
±±
[
±
]/[
±
]:Up/Down
±±
±±
[SELECT]:Enter
p