Yamaha MA2120 MA2120 Setup Guide - Page 8

Setup Mode (Advanced settings), Setup Mode Operation Procedure, Indication of Parameter Settings

Page 8 highlights

Setup Mode (Advanced settings) Advanced settings for MA2120 power amplifier can be configured by using the [SETUP] encoder and input level knobs 1 - 8. Input level knobs 1 - 8 [SETUP] encoder There are three types of setup modes that can be used to configure advanced settings. Operation and functionality for each setup mode type is shown as follows: • Input channel setup mode  Press and hold the [SETUP] encoder for at least one second. Microphone high-pass filter, microphone compressor, input EQ (TREBLE, BASS), reverb, ducker, leveler • Output zone setup mode  Press and hold the [SETUP] encoder and input level knob 1 simultaneously for at least one second. Chime volume, linked operation of [SPEAKERS] and [LINE OUT] • Other setup mode  Press and hold the [SETUP] encoder and input level knob 2 simultaneously for at least one second. Feedback suppressor, DCP setup Setup Mode Operation Procedure Advanced settings can be configured with the following procedure: Select the setup mode  Select the function  Select the channel  [SETUP] encoder Input level knobs 1 and 2 Input level knobs 1 - 8 Input level knobs 1 - 8 Set parameters [SETUP] encoder Once each operation is carried out successfully, the corresponding indicator flashes three times at high speed. When selecting functions or channels, the indicator flashes slowly to indicate which functions or channels are able to be selected. While adjusting a parameter, you can press an input level knob so that the corresponding [INPUT SIG] indicator (showing the selected function) and [INPUT PEAK] indicator (showing the selected channel) both flash. Apply the parameter and return to channel selection  Return to function selection  Return to conventional operation [SETUP] encoder [SETUP] encoder [SETUP] encoder After you set the parameter, press the [SETUP] encoder to confirm the setting. At this time, press and hold the [SETUP] encoder for at least four seconds to reset the current parameter to the default setting. Once the parameter has been confirmed, the device mode returns to the channel selection. Press the [SETUP] encoder again to return to the function selection, and once more to return to the regular mode. Indication of Parameter Settings In setup mode, the current settings are indicated by the three indicators above the [SETUP] encoder. The indicators can turn on or flash to show the on/off state or the currently set value. In addition, depending on the parameter value, the flashing behavior may differ. For example, when the delay time of echo set is increased, the lighting time during flashing becomes longer. In this guide, the behavior of the indicators is shown as follows. : Lights continuously : Flashes : Off 8 MA2120 Setup Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

8
MA2120 Setup Guide
Setup Mode (Advanced settings)
Advanced settings for MA2120 power amplifier can be configured by using the [SETUP] encoder and input level knobs 1 - 8.
There are three types of setup modes that can be used to configure advanced settings. Operation and functionality for each setup mode
type is shown as follows:
Input channel setup mode
±
Press and hold the [SETUP] encoder for at least one second.
Microphone high-pass filter, microphone compressor, input EQ (TREBLE, BASS), reverb, ducker, leveler
Output zone setup mode
±
Press and hold the [SETUP] encoder and input level knob 1 simultaneously for at least one
second.
Chime volume, linked operation of [SPEAKERS] and [LINE OUT]
Other setup mode
±
Press and hold the [SETUP] encoder and input level knob 2 simultaneously for at least one second.
Feedback suppressor, DCP setup
Advanced settings can be configured with the following procedure:
Once each operation is carried out successfully, the corresponding indicator flashes three times at high speed.
When selecting functions or channels, the indicator flashes slowly to indicate which functions or channels are able to be selected.
While adjusting a parameter, you can press an input level knob so that the corresponding [INPUT SIG] indicator (showing the selected
function) and [INPUT PEAK] indicator (showing the selected channel) both flash.
After you set the parameter, press the [SETUP] encoder to confirm the setting.
At this time, press and hold the [SETUP] encoder for at least four seconds to reset the current parameter to the default setting.
Once the parameter has been confirmed, the device mode returns to the channel selection. Press the [SETUP] encoder again to return
to the function selection, and once more to return to the regular mode.
In setup mode, the current settings are indicated by the three indicators above the [SETUP] encoder.
The indicators can turn on or flash to show the on/off state or the currently set value. In addition, depending on the parameter value, the
flashing behavior may differ. For example, when the delay time of echo set is increased, the lighting time during flashing becomes longer.
In this guide, the behavior of the indicators is shown as follows.
: Lights continuously
: Flashes
: Off
[SETUP] encoder
Input level knobs 1 - 8
Setup Mode Operation Procedure
Select the setup mode
±
Select the function
±
Select the channel
±
Set parameters
[SETUP] encoder
Input level knobs 1 and 2
Input level knobs 1 - 8
Input level knobs 1 - 8
[SETUP] encoder
Apply the parameter and return to channel selection
±
Return to function selection
±
Return to conventional operation
[SETUP] encoder
[SETUP] encoder
[SETUP] encoder
Indication of Parameter Settings