Yamaha MDX-E100 Owner's Manual - Page 11

RECORDING, Insert an MD. - natural sound

Page 11 highlights

English RECORDING This unit allows you to make recordings from a wide variety of program sources (both analog and digital). When recording an analog source (such as an FM broadcast or cassette) this unit converts the analog signals to a 44.1 kHz digital signal before recording them onto the MD. When recording a digital source, this unit converts the digital signals to 44.1 kHz for recording onto the MD. However, if you are recording a 44.1 kHz source signal (such as a CD) there is no conversion. This unit can record 32, 44.1 and 48 kHz digital signals. Preparations • Press STANDBY/ON (POWER on the remote) to turn this unit on. • Set the RX-E100 to the program source to be recorded. 1 NATURAL SOUND MINIDISC RECORDER MDX-E100 STANDBY/ON &7 5 / INPUT REC/PAUSE REC LEVEL ANALOG - DIGITAL + MIN MAX STANDBY/ON 2 6 6 DELETE/ CANCEL 7 5 M-MARK POWER TITLE DELETE SET CANCEL ENTER CHAR NUMBER EDIT ABC DEF 1 2 G H I 3 J K L 4 MNO PQR STU VWX 5 6 7 8 Y Z / SPACE 9 0 +10 +100 REC/ PAUSE SYNC M-MARK MONO/ST INPUT RANDOM PROGRAM REPEAT A-B S/F DISPLAY SCROLL POWER SET/ENTER * & 2 1 Insert an MD. Label facing up Arrow pointed toward disc insertion slot 2 Press INPUT repeatedly to select the input you want to record. For ANALOG IN Î DIGITAL IN OPTICAL 1 DIGITAL IN OPTICAL 2 Select ANALOG DIGITAL OPT. 1 DIGITAL OPT. 2 Input indicator ANALOG DISC TRACK DIGITAL TOTAL OPT.123 REMAIN COAX. 32 44.1 48 kHz RANDOM PROGRAM MONO REC REPEAT A-B S F MANUAL L dB -00 -60 -30 -10 -6 4 -2 -1 0 OVER TOC R (Source) sampling frequency indicators* * Appears when digital signal is input. 3 Locate the point where you want to start recording. • When recording on a blank MD Skip this step. • To start recording from the end of a previous recording Press & to set this unit to stop mode. • To record over a previous recording Turn the jog dial (or press $ or › on the remote) to select a track (recording starts from the beginning of the deleted track). 4 Start playing the source to be recorded. If you do not need to adjust the recording level, this step is not necessary. 5 Press REC/PAUSE to set this unit to record pause mode. The REC * indicators light up. "REC Standby" and the amount of time available for recording flash alternately in the display. If you selected a track number (in step 3) to record over a previous recording "OverWrite OK?" appears in the display. To confirm, press SET/ENTER. This operation will erase the selected track number (or point) and all subsequent material. To cancel, press DELETE/CANCEL (or &). Continued on next page E-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

E-11
English
RECORDING
This unit allows you to make recordings from a wide
variety of program sources (both analog and digital).
When recording an analog source (such as an FM
broadcast or cassette) this unit converts the analog
signals to a 44.1 kHz digital signal before recording
them onto the MD.
When recording a digital source, this unit converts the
digital signals to 44.1 kHz for recording onto the MD.
However, if you are recording a 44.1 kHz source signal
(such as a CD) there is no conversion. This unit can
record 32, 44.1 and 48 kHz digital signals.
Preparations
• Press
STANDBY/ON
(
POWER
on the remote) to
turn this unit on.
Set the RX-E100 to the program source to be
recorded.
1
Insert an MD.
2
Press
INPUT
repeatedly to select the input
you want to record.
For
Select
ANALOG IN
Î
ANALOG
DIGITAL IN OPTICAL 1
DIGITAL OPT. 1
DIGITAL IN OPTICAL 2
DIGITAL OPT. 2
*
Appears when digital signal is input.
3
Locate the point where you want to start
recording.
When recording on a blank MD
Skip this step.
To start recording from the end of a previous
recording
Press
&
to set this unit to stop mode.
To record over a previous recording
Turn the jog dial (or press
$
or
on the remote) to
select a track (recording starts from the beginning of the
deleted track).
4
Start playing the source to be recorded.
If you do not need to adjust the recording level, this step is
not necessary.
5
Press
REC/PAUSE
to set this unit to record
pause mode.
The REC
*
indicators light up.
“REC Standby” and the amount of time available for
recording flash alternately in the display.
If you selected a track number (in step 3) to
record over a previous recording
“OverWrite OK?” appears in the display.
To confirm, press
SET/ENTER
.
This operation will erase
the selected track number (or point) and all subsequent
material.
To cancel, press
DELETE/CANCEL
(or
&
).
Input indicator
(Source) sampling frequency indicators*
Arrow pointed toward
disc insertion slot
Label facing up
1
2
5
7
2
5
M-MARK
&
7
&
*
/
STANDBY/ON
NATURAL SOUND
MINIDISC RECORDER
MDX-E100
INPUT
ANALOG
DIGITAL
REC LEVEL
MIN
MAX
REC/PAUSE
+
TITLE
DELETE
SET
CANCEL
ENTER
EDIT
CHAR NUMBER
A B C
D E F
G H I
J K L
1
2
3
4
5
6
7
8
9
0
+10
+100
A-B
S/F
DISPLAY
POWER
SCROLL
M N O
P Q R
S T U
V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK
MONO/ST
INPUT
RANDOM PROGRAM
REPEAT
DELETE/
CANCEL
SET/ENTER
ANALOG
DIGITAL
OPT.1
23
COAX.
32
44.1
48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60
30
10
6
4
2
1
0
OVER
00 –
POWER
STANDBY/ON
6
6
Continued on next page