Zanussi ZDE67560W Product Manaul - Page 12

Installation - vented tumble dryer

Page 12 highlights

Energy efficiency class C Power consumption Left-on mode 0,70 W Off-mode 0,70 W 1) With reference to EN 61121. 7 kg of cotton and a spin speed at 1000 rpm. 2) Energy consumption per year in kWh, based on 160 drying cycles of the standard cotton programme at full and partial load, and the consumption of the low-power modes. Actual energy consumption per cycle will depend on how the appliance is used (REGULATION (EU) No 392/2012). Installation Appliance positioning • It is recommended that, for your convenience, the appliance is positioned close to your washing machine. • The tumble dryer must be installed in a clean place, where dirt does not build up. • Air must be able to circulate freely all round the appliance. Do not obstruct the front ventilation grille or the air intake grilles at the back of the appliance. • To keep vibration and noise to a minimum when the tumble dryer is in use, it should be placed on a firm, level surface. • Once in its permanent operating position, check that the tumble dryer is absolutely level with the aid of a spirit level. If it is not, raise or lower the feet until it is. • The feet must never be removed. Do not restrict the floor clearance through deep pile carpets, strips of wood or similar. This might cause heat built-up which would interfere with the operation of the appliance. Important! • The hot air emitted by the tumble dryer can reach temperatures of up to 60°C. The appliance must therefore not be installed on floors which are not resistant to high temperatures. • When operating the tumble dryer, the room temperature must not be lower than +5°C and higher than +35°C, as it may affect the performance of the appliance. • Should the appliance be moved, it must be transported vertically. • The appliance must not be installed behind a lockable door, a sliding door a door with a 12 hinge on the opposite side to that of the appliance in such a way that a full opening of the tumble dryer is restricted. Removing transport safety packaging Caution! Before use all parts of the transport packaging must be removed. 1. Open loading door. 3. Remove foil hose 2. Pull off adhesive and polystyrene padstrips from inside ma- ding from the machine on top of drum. chine. Fitting the vent hose To simplify the installation, there is a choice of vent outlets: one at the back, the others in the left and right-hand side. Connect the hose to whichever is the more convenient by pulling the ring nut (A) from the vent outlet at the back, screwing it on to the hose and pushing it firmly back into place. The unused vents should now be sealed with the special snap covers provided. www.zanussi.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Energy efficiency class
C
Power consumption
Left-on mode
0,70 W
Off-mode
0,70 W
1)
With reference to EN 61121. 7 kg of cotton and a spin speed at 1000 rpm.
2)
Energy consumption per year in kWh, based on 160 drying cycles of the standard cotton programme at full
and partial load, and the consumption of the low-power modes. Actual energy consumption per cycle will
depend on how the appliance is used (REGULATION (EU) No 392/2012).
Installation
Appliance positioning
It is recommended that, for your convenience,
the appliance is positioned close to your
washing machine.
The tumble dryer must be installed in a clean
place, where dirt does not build up.
Air must be able to circulate freely all round
the appliance. Do not obstruct the front venti-
lation grille or the air intake grilles at the back
of the appliance.
To keep vibration and noise to a minimum
when the tumble dryer is in use, it should be
placed on a firm, level surface.
Once in its permanent operating position,
check that the tumble dryer is absolutely level
with the aid of a spirit level. If it is not, raise or
lower the feet until it is.
The feet must never be removed. Do not re-
strict the floor clearance through deep pile
carpets, strips of wood or similar. This might
cause heat built-up which would interfere
with the operation of the appliance.
Important!
The hot air emitted by the tumble dryer can
reach temperatures of up to 60°C. The appli-
ance must therefore not be installed on floors
which are not resistant to high temperatures.
When operating the tumble dryer, the room
temperature must not be lower than +5°C
and higher than +35°C, as it may affect the
performance of the appliance.
Should the appliance be moved, it must be
transported vertically.
The appliance must not be installed behind a
lockable door, a sliding door a door with a
hinge on the opposite side to that of the ap-
pliance in such a way that a full opening of
the tumble dryer is restricted.
Removing transport safety packaging
Caution!
Before use all parts of the
transport packaging must be removed.
1. Open loading door.
2. Pull off adhesive
strips from inside ma-
chine on top of drum.
3. Remove foil hose
and polystyrene pad-
ding from the ma-
chine.
Fitting the vent hose
To simplify the installation, there is a choice of
vent outlets: one at the back, the others in the
left and right-hand side. Connect the hose to
whichever is the more convenient by pulling the
ring nut (A) from the vent outlet at the back,
screwing it on to the hose and pushing it firmly
back into place. The unused vents should now
be sealed with the special snap covers provi-
ded.
12