Zanussi ZOA35471XK User Manual - Page 4
Electrical Connection, Use, H07 Rn-f - installation
View all Zanussi ZOA35471XK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Mounting screws 4x25 mm ELECTRICAL CONNECTION WARNING! Risk of fire and electric shock. • All electrical connections should be made by a qualified electrician. • The appliance must be earthed. • Make sure that the parameters on the rating plate are compatible with the electrical ratings of the mains power supply. • Always use a correctly installed shockproof socket. • Do not use multi-plug adapters and extension cables. • Make sure not to cause damage to the mains plug and to the mains cable. Should the mains cable need to be replaced, this must be carried out by our Authorised Service Centre. • Do not let mains cables touch or come near the appliance door or the niche below the appliance, especially when it operates or the door is hot. • The shock protection of live and insulated parts must be fastened in such a way that it cannot be removed without tools. • Connect the mains plug to the mains socket only at the end of the installation. Make sure that there is access to the mains plug after the installation. • If the mains socket is loose, do not connect the mains plug. • Do not pull the mains cable to disconnect the appliance. Always pull the mains plug. • Use only correct isolation devices: line protecting cut-outs, fuses (screw type fuses removed from the holder), earth leakage trips and contactors. • The electrical installation must have an isolation device which lets you disconnect the appliance from the mains at all poles. The isolation device must have a contact opening width of minimum 3 mm. • This appliance is supplied without a main plug and a main cable. Cable types applicable for installation or replacement for Europe: H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-F (T90), H05 BB-F For the section of the cable refer to the total power on the rating plate. You can also refer to the table: Total power (W) Section of the cable (mm²) maximum 1380 maximum 2300 maximum 3680 3 x 0.75 3 x 1 3 x 1.5 The earth cord (green / yellow cable) must be 2 cm longer than phase and neutral cables (blue and brown cables). Cable types applicable for installation or replacement for UK only Connection Min. size ca- Cable / flex via ble / flex type / Fuse Oven Control Circuit 2,5 mm² PVC / PVC twin and earth / 15 A min. PVC / PVC twin and earth / 20 A max. UK and Ireland only. This appliance is fitted with a 13 A mains plug. If it is necessary to change the mains plug fuse, use only a 13 A ASTA (BS 1362) fuse. Minimum size cable / flex: 1,5 mm² . USE WARNING! Risk of injury, burns and electric shock or explosion. • This appliance is for household use only. • Do not change the specification of this appliance. • Make sure that the ventilation openings are not blocked. • Do not let the appliance stay unattended during operation. • Deactivate the appliance after each use. • Be careful when you open the appliance door while the appliance is in operation. Hot air can release. • Do not operate the appliance with wet hands or when it has contact with water. • Do not apply pressure on the open door. • Do not use the appliance as a work surface or as a storage surface. 4