MC100FX-SC2/30-A User's Guide Make sure that the cables are connected properly before getting started. Conduct either the local or remote test, not both at the same time. Follow the steps below to perform the diagnostic tests. Local Loop-back 1. Test Condition set-up - for an accurate result, be sure to set the DIP switches according to the table below: Test Condition DIP Switches 1 23 45 6 Converter A OFF FD 100 FD OFF ON 7 OFF Converter B OFF FD 100 FD OFF OFF OFF 2. Launch a loop-back or diagnostics testing program and follow the instructions given. Typically, the instructions will be similar to the following: z Enter the number of test messages (frame packets) to be sent (between 1 and 1000). z Click on the START button. z The program will send a testing message that will loop in the copper segment - it will then display a pass/fail result. Remote Loop-back 1. Test Condition set-up - to produce an accurate result, set switches according to the table below: Test Condition DIP Switches 1 2 3 4 5 6 7 Converter A OFF FD 100 FD OFF OFF OFF Converter B OFF FD 100 FD OFF OFF ON 9