48 ABACUS (EN) Maximum Function Times - Channel 1 & Channel 4 Control(s) and Attenuverter set to maximum (fully CW) Rise Time Rise Peak Fall Time Fall Min Cycle Time Log 9 m 0 s 9.48 v 25 m 15 s 0.03 v 42 m 45 s Lin 55 s 9.48 v 50 s 0.03 v 1 m 45 s Exp 7 s 4.5 v 5 s 0.03 v 10 s Hints and Tips • Channels 1 and 4 can be used to modulate each other's Rise, Fall or Both functions. • Channel 4's EOC trigger can be used to trigger an external Sample & Hold generator which could then be used as a modulation source. • Channel 1's EOR output can be used as a modifier to any CV input on channels 1 and 4; or as an external voltage input to any channel. • Channels 2 and 3 can be used to provide an offset voltage for the CV inputs of Channel 1 and 4. • Experiment with the inverted sum voltage as a control source. (ES) Tiempos máximos de función - Canal 1 y Canal 4 Control(es) y atenuadores/inversores ajustados al máximo (tope derecho) Tiempo Rise Pico Rise Tiempo Fall Mínimo Fall Tiempo Cycle Log 9 m 0 s 9.48 v 25 m 15 s 0.03 v 42 m 45 s Lin 55 s 9.48 v 50 s 0.03 v 1 m 45 s Exp 7 s 4.5 v 5 s 0.03 v 10 s Quick Start Guide 49 Notas y avisos • Puede usar los canales 1 y 4 para modular las funciones Rise, Fall o Both del otro canal. • Puede usar el disparador EOC del canal 4 para conmutar un generador S&H (muestreo y mantenimiento) que puede usar después como una fuente de modulación. • Puede usar la salida EOR del canal 1 como un modificador para cualquier entrada CV de los canales 1 y 4, o como una entrada de voltaje externo para cualquier canal. • Puede usar los canales 2 y 3 para ofrecer un voltaje de desfase u offset para las entradas CV del canal 1 y 4. • Experimente con el voltaje de suma invertido como una fuente de control. (FR) Durée maximale des fonctions - Canal 1 et canal 4 Réglage(s) et atténuateur/inverseur au maximum (tournés complètement à droite) Durée de Rise Rise Max Durée de Fall Fall Min Durée du cycle Log 9 m 0 s 9.48 v 25 m 15 s 0.03 v 42 m 45 s Lin 55 s 9.48 v 50 s 0.03 v 1 m 45 s Exp 7 s 4.5 v 5 s 0.03 v 10 s Trucs et astuces • Les canaux 1 et 4 peuvent être utilisés pour moduler leurs fonctions Rise, Fall ou Both. • Le déclencheur EOC du canal 4 peut être utilisé pour déclencher un générateur externe de Sample & Hold pouvant ensuite être utilisé comme source de modulation. • La sortie EOR du canal 1 peut être utilisée pour moduler les entrées CV des canaux 1 et 4 ou comme générateur externe de tension pour tous les canaux.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

48
49
Quick Start Guide
ABACUS
(EN)
Maximum Function Times – Channel 1 & Channel 4
Control(s) and Attenuverter set to maximum (fully CW)
Rise Time
Rise Peak
Fall Time
Fall Min
Cycle
Time
Log
9 m 0 s
9.48 v
25 m 15 s
0.03 v
42 m 45 s
Lin
55 s
9.48 v
50 s
0.03 v
1 m 45 s
Exp
7 s
4.5 v
5 s
0.03 v
10 s
Hints and Tips
Channels 1 and 4 can be used to modulate each other’s Rise, Fall or
Both functions.
Channel 4’s EOC trigger can be used to trigger an external Sample & Hold
generator which could then be used as a modulation source.
Channel 1’s EOR output can be used as a modifier to any CV input on
channels 1 and 4; or as an external voltage input to any channel.
Channels 2 and 3 can be used to provide an offset voltage for the CV inputs
of Channel 1 and 4.
Experiment with the inverted sum voltage as a control source.
(ES)
Tiempos máximos de función – Canal 1 y Canal 4
Control(es) y atenuadores/inversores ajustados al máximo (tope derecho)
Tiempo
Rise
Pico Rise
Tiempo
Fall
Mínimo
Fall
Tiempo
Cycle
Log
9 m 0 s
9.48 v
25 m 15 s
0.03 v
42 m 45 s
Lin
55 s
9.48 v
50 s
0.03 v
1 m 45 s
Exp
7 s
4.5 v
5 s
0.03 v
10 s
Notas y avisos
Puede usar los canales 1 y 4 para modular las funciones Rise, Fall o Both
del otro canal.
Puede usar el disparador EOC del canal 4 para conmutar un generador S&H
(muestreo y mantenimiento) que puede usar después como una fuente
de modulación.
Puede usar la salida EOR del canal 1 como un modificador para cualquier
entrada CV de los canales 1 y 4, o como una entrada de voltaje externo para
cualquier canal.
Puede usar los canales 2 y 3 para ofrecer un voltaje de desfase u offset para
las entradas CV del canal 1 y 4.
Experimente con el voltaje de suma invertido como una fuente de control.
(FR)
Durée maximale des fonctions – Canal 1 et canal 4
Réglage(s) et atténuateur/inverseur au maximum (tournés complètement
à droite)
Durée de
Rise
Rise Max
Durée de
Fall
Fall Min
Durée du
cycle
Log
9 m 0 s
9.48 v
25 m 15 s
0.03 v
42 m 45 s
Lin
55 s
9.48 v
50 s
0.03 v
1 m 45 s
Exp
7 s
4.5 v
5 s
0.03 v
10 s
Trucs et astuces
Les canaux 1 et 4 peuvent être utilisés pour moduler leurs fonctions Rise,
Fall ou Both.
Le déclencheur EOC du canal 4 peut être utilisé pour déclencher un
générateur externe de Sample & Hold pouvant ensuite être utilisé comme
source de modulation.
La sortie EOR du canal 1 peut être utilisée pour moduler les entrées CV des
canaux 1 et 4 ou comme générateur externe de tension pour tous
les canaux.