Behringer X32-TP Quickstart Guide - Page 16

Setting up S16 Stagebox - x32 presets

Page 16 highlights

Setting up S16 Stagebox 1. Connect the AES50 (A) port on the back of the X32 to the AES50 (A) port on the back of the S16 stagebox. If using two S16s, connect the AES50 (B) port on the first S16 to the AES50 (A) port on the second S16. This allows the X32 to control the S16 preamps remotely. Note that you will need to configure the S16s for external sync and the X32 for local sync, set this on the "config" tab of the SETUP menu. You will also need the first S16 in Operational Mode 1 and the second S16 in Operational Mode 2, (other modes are available). Please check the S16 Quick Start Guide for more information. 2. Press the ROUTING button and while viewing the "home" page, press UTILITY. 3. Use the 2nd rotary encoder to select the AES50 A Inputs preset and press the encoder to load. 4. Page right to AES50 (A) output. Check that "Out 1-8" and "Out 9-16" are assigned to the first two banks of outputs. These outputs will mirror the 16 analog outs on the X32, configured from the "analog out" tab of the ROUTING menu. 5. The P16 signal is carried over AES50 outputs 32-48 by default to the ULTRANET port on the S16. • 32 x 16 plus 16 channels for P-16 Personal Monitoring, over a SINGLE ETHERNET CABLE!.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Setting up S16 Stagebox
1. Connect the AES50 (A) port on the back of the X32 to the AES50 (A) port on the back of the S16 stagebox.
If using two S16s, connect the AES50 (B) port on the first S16 to the AES50 (A) port on the second S16.
This allows the X32 to control the S16 preamps remotely. Note that you will need to configure the S16s for
external sync and the X32 for local sync, set this on the “config” tab of the SETUP menu. You will also need the
first S16 in Operational Mode 1 and the second S16 in Operational Mode 2, (other modes are available).
Please check the S16 Quick Start Guide for more information.
2. Press the ROUTING button and while viewing the “home” page, press UTILITY.
3. Use the 2nd rotary encoder to select the AES50 A Inputs preset and press the encoder to load.
4. Page right to AES50 (A) output. Check that “Out 1-8” and “Out 9-16” are assigned to the first two banks of outputs.
These outputs will mirror the 16 analog outs on the X32, configured from the “analog out” tab of the ROUTING menu.
5. The P16 signal is carried over AES50 outputs 32-48 by default to the ULTRANET port on the S16.
32 x 16 plus 16 channels for P-16 Personal Monitoring, over a SINGLE ETHERNET CABLE!.