BenQ BenQ HC1200 sRGB DLP Projector User Manual - Page 57
Resetting the lamp timer, Ensure the handle is fully laid flat
View all BenQ BenQ HC1200 sRGB DLP Projector manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
5. Lift the handle so that it stands up. Use the handle to slowly pull the lamp out of the projector. • Pulling it too quickly may cause the lamp to break and scatter broken glass in the projector. • Do not place the lamp in locations where water might splash on it, children can reach it, or near flammable materials. • Do not insert your hands into the projector after the lamp is removed. If you touch the optical components inside, it could cause color unevenness and distortion of the projected images. 6. Insert the new lamp into the lamp compartment and make sure it fits in the projector. • Ensure the connectors are aligned. • If you experience resistance, lift the lamp and start again. 7. Tighten the screws that secure the lamp. 8. Ensure the handle is fully laid flat and locked in place. • Loose screw may cause a bad connection, which could result in malfunction. • Do not over tighten the screw. 9. Replace the lamp compartment cover on the projectorand tighten the captive screw. 10. Restart the projector. Do not turn the power on with the lamp cover removed. Resetting the lamp timer Maintenance 57