Page 30 highlights
24" LCD Color Monitor BenQ Service Page BenQ E2400HD 1. Trigger method: Press "Menu" key and Power on. 2. Press the Menu key will display the service page 3. Press menu key will close the service page. 4. power off will quit the service mode 5. At the service mode, the key function is same as normal OSD define. 6. The timer can only reset at the service mode by " Timer Reset". And need to have a warning message to double confirm the reset function.The timer should record up to 99999 hours 7. Add one select item for HDCP(DVI port),Mode1,Mode2 at Service menu Mode1: To enable the hot plug pin detection.(HDMI port default) Mode 2: To disable the hot plug pin detection.(DVI port default) 8. add BenQ logo on/off item, the default is "on" 9. add the auto power on item, the default is "off " 10. Add the timer reset warning message, when select the timer reset item, then the warning message will display and need to confirm it again and the default is "No". 11. Panel type define need to have the panel version 12. F/W version need to define the dual or analog model. 30