Bosch DHR-1600A-150A User Manual - Page 27
Logbook - disconnect
View all Bosch DHR-1600A-150A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Divar XF 3.9.2 Operating instructions | en 27 Alarm recording at input - displays which inputs are in alarm recording mode Motion recording at input - displays which inputs are in motion recording mode Current recording status - displays video and audio recording status and mode for each input Sensors Displays actual temperature and voltage sensor values. If temperature levels are outside of the normal range, the displayed values are yellow. If this occurs, check that the ambient temperature is within the recommended specifications and that there is proper air ventilation. If the temperature reaches a critical level, the unit automatically shuts down. To restart the unit, disconnect the power cord, wait for at least 30 seconds, and then reconnect the power cord. Sensor name Processor Air inlet Air outlet Hard disk #1 Hard disk #2 Hard disk #3 Hard disk #4 Table 3.1 Temperature sensors Lower limit 5 °C / 41 °F 5 °C / 41 °F 5 °C / 41 °F 5 °C / 41 °F 5 °C / 41 °F 5 °C / 41 °F 5 °C / 41 °F Upper limit 100 °C / 212 °F 45 °C / 113 °F 55 °C / 131 °F 55 °C / 131 °F 55 °C / 131 °F 55 °C / 131 °F 55 °C / 131 °F Voltage level 12 Volt 5 Volt 3.3 Volt Table 3.2 Power supply levels Logbook Lower limit 10.8 V 4.7 V 3.1 V Upper limit 13.2 V 5.3 V 3.5 V The logbook menu is used to display a filtered history of system events. Logbook filter Set various filter criteria to search in a specified time period for various system events. Bosch Security Systems User manual F.01U.135.431 | 2.5 | 2009.08