Brother International BAS-300A Application Instruction Manual - English - Page 35
check, speed, split, which, already, programmed, erase, conversion, optional, output
View all Brother International BAS-300A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
El To check low speed data and split data which have already been programmed [E] • After programming is completed but before the program is written to disk, the setting for any desired needle position can be indicated on the display by pressing the 0 key at that position. a El I STEP t Indicates the number of stitches remaining from the needle position (in units of 10 stitches). - Indicates the feed data setting. Indicates the optional output setting. 0: No setting 1 : "771"E 2: "772"ED 3 : "773"E 0 : Normal feed 6 : Split (19"666") 8 : Split with no thread trimming (I"888") 9 : basting (0"999") Indicates the low speed conversion setting. 0: No setting 6: "666"E 7 : "6671: In To erase low speed conversion data and optional output data which have already been programmed • Check the data according to section N. • Erase the low speed conversion data by inputting "660" a • Erase the optional output data by inputting "770" IE. -32-