Fuse 6A-250A, After measurement, turn off the power wait at least 5
View all Brother International BAS-311E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 111 highlights
Chapter 7 Error status Probable causes 4. Fuse has blown Check/repair/adjust • Remove fuses No.3 and No.4, and check them for continuity. If there is no continuity, replace the fuses with new ones, and perform the check/repair/adjust items of #1-5. Parts to be replaced Fuse 6A-250A 5. Power supply circuit board ɹdefective #1 continued • Separate P4 (ACIN) connectors on the power supply circuit board, and then measure the resistance between the followinɹoth cases, the power supply circuit board is not defective. • Measure the resistance between pins 1 and 2. If there is not short, the power supply circuit board is not defective. • rejoin P4 (ACIN) connectors on the power supply circuit board. Separate P3 (POWER) connectors on the main circuit board, turn on the power, and measure the voltage across pins 1 and 3 in the connector on the cable. If it is + 5V, the power circuit board is not defective. After measurement, turn off the power wait at least 5 minutes, and then rejoin P3 connectors. Power supply circuit board 6. Control circuit board defective • With P3 (POWER) connectors plugged in on the control circuit board, turn on the power, and measure the voltage across pins 1 and 3 in the connector on the cable. If it is + 5V, the power circuit board is not defective. After measurement, turn off the power. Control circuit board 7. Panel circuit board defective • Check that P18 (PANEL) connectors of the main circuit Panel circuit board board and P5 (DRV) connectors of the panel circuit board are plugged in. BAS-311E.311EL.326E.326EL 103