Brother International BAS-311E Network Users Manual - English - Page 55
Replace the H-position standard plate, Press the P key to be out of the program mode
View all Brother International BAS-311E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Chapter 3. Assembly !4 !1 0.1 - 0.5mm !8 !7 H - position (X=0, Y=0) 12.Press the P key and adjust the X-sensor setting plate !7 so that the needle !4 is aligned with the home position (X=0, Y=0) of the H-position standard plate !1. 13.Press the P key again to make sure that the needle !4 is aligned with the home position (X=0, Y=0) of the H-position standard plate !1. 14.Secure the X-sensor setting plate !7 using the screw. 15.Remove the needle !4. 16.Press the P key to be out of the program mode, and turn off the power. 17.Replace the H-position standard plate !1 with the work clamp. Note: When adjusting the X home position, be sure to set the clearance between the X-home position dog !8 and the surface where the sensor is activated to 0.1 - 0.5 mm. If the clearance is too great, an error in home position detection may occur because the temperature of the sewing machine rises during sewing operation. BAS-311E.311EL.326E.326EL 47