Brother International MFC 9060 Service Manual - Page 110
U.S.A. type, WSW17
UPC - 012502040064
View all Brother International MFC 9060 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW17 (Function setting 2) Function Off-hook alarm Power failure report output Calendar clock/prompt alternate display Calendar clock type Not used. Non-ring reception Not used. Setting and Specifications No. 1 0 0 1 0: 2 0: 1: X: ON No alarm Always valid Valid except when 'call reservation' is selected. 1: OFF 0: No 1: Yes 0: U.S.A. type 1: European type 0: OFF 1: ON NOTE: Selector 4 is not applicable to those models having a 2-row LCD. Selectors 1 and 2: Off-hook alarm These selectors activate or deactivate the alarm function which sounds an alarm when the communication is completed with the handset being off the hook. Selector 3: Power failure report output This selector determines whether or not the equipment outputs a power failure report when the power comes back on. Selector 4: Calendar clock/prompt alternate display If this selector is set to "1," the calendar clock and the prompt "INSERT DOCUMENT" appear alternately on the LCD while the equipment is on standby; if it is set to "0," only the calendar clock appears. Selector 5: Calendar clock type If this selector is set to "0" (USA), the MM/DD/YY hh:mm format applies; if it is set to "1" (Europe), the DD/MM/YY hh:mm format applies: DD is the day, MM is the month, YY is the last two digits of the year, hh is the hour, and mm is the minute. Selector 7: Non-ring reception Setting this selector to "1" makes the equipment receive calls without ringer sound if the ring delay is set to 0. V - 30