Brother International MFC 9060 Service Manual - Page 129
WSW37 to WSW44, WSW45 Function setting 23, cold approx. 45
UPC - 012502040064
View all Brother International MFC 9060 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Selector No. 1 | 8 Function Not used. WSW37 to WSW44 Setting and Specifications WSW45 (Function setting 23) Selector No. 1 | 8 Function Setting and Specifications Definition of the time lag in the start of main motor drive when the heater of the heat-fixing unit is cold Set half of the value of the desired time lag to these selectors in binary notation. No. 1 2 3 4 000 0 000 0 | 000 0 | 111 1 5 6 78 0 0 00 0 0 01 0 1 10 1 1 11 : No lag : 2 sec. | : 12 sec. | : 510 sec. WSW46 (Function setting 24) Selector No. 1 | 8 Function Idle time of the main motor when the power is first applied Setting and Specifications Set half of the value of the desired idle time to these selectors in binary notation. No. 1 2 3 4 000 0 000 0 | 000 0 | 111 1 5 6 78 0 0 00 0 0 01 0 1 10 1 1 11 : No idle time : 2 sec. | : 12 sec. | : 510 sec. Selector No. 1 | 8 WSW47 (Function setting 25) Function Idle time of the main motor when the heater of the heat-fixing unit is cold (approx. 45°C or below) Setting and Specifications Set half of the value of the idle time to these selectors in binary notation. No. 1 2 3 4 000 0 000 0 | 000 0 | 111 1 5 6 78 0 0 00 0 0 01 0 1 10 1 1 11 : No idle time : 2 sec. | : 12 sec. | : 510 sec. V - 49