Canon imageFORMULA DR-7580 User Manual - Page 88
Carefully close the upper scanner.
View all Canon imageFORMULA DR-7580 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Chapter 7 Daily Cleaning 8 Replace the rollers that you removed. (See "Installing and Removing the Rollers," on p.91.) 9 Carefully close the upper scanner. 10 Press the upper scanner down firmly on both sides to close it. If you press the upper scanner down only on one side, the opposite side will not be fully closed. Make sure that you hear it click into place. Important If paper jams or double-feed (feeding of two or more document pages) occurs frequently in spite of your having cleaned the rollers, a probable cause is roller friction. If this happens, replace the rollers. Contact your service representative. 84
84
Chapter 7
Daily Cleaning
8
Replace the rollers that you removed. (See “Installing and
Removing the Rollers,” on p.91.)
9
Carefully close the upper scanner.
10
Press the upper scanner down firmly on both sides to close it.
If you press the upper scanner down only on one side, the opposite side
will not be fully closed. Make sure that you hear it click into place.
If paper jams or double-feed (feeding of two or more document pages) occurs
frequently in spite of your having cleaned the rollers, a probable cause is roller
friction. If this happens, replace the rollers. Contact your service representative.
Important