HotPlug Drive Fans, IMPORTANT, CAUTION - ml530 hot plug drive fan
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Removal and Replacement Procedures 2-17 Hot-Plug Drive Fans Three hot-plug drive fans come standard with Compaq ProLiant ML530 servers. IMPORTANT: It is not necessary to power down the server to replace hot-plug devices such as power supplies, fans, or hard drives when they are not in active use. NOTE: The hot-plug drive fan looks similar to the fan used in the Compaq ProLiant 6400R server, but operates differently. The Compaq ProLiant 6400R fan is not compatible in Compaq ProLiant ML530 servers. To remove a hot-plug drive fan: 1. Perform the preparation procedures. See "Hot-Pluggable Device" earlier in this chapter. 2. Remove the access panel. See "Access Panel" earlier in this chapter. 3. Press the thumb latch adjacent to the system board tray handle to release the system board tray. Using the system board tray handle, pull the tray partially out of the chassis to access the hot-plug drive fans. CAUTION: Hot-plug hard drive fans are located below the server cabling. Be careful not to inadvertently unplug or loosen cables when accessing hot-plug drive fans. 4. Loosen the thumbscrew located at the top of the fan. 5. Lift the hot-plug drive fan out of the chassis . 1 2 Figure 2-10. Removing a hot-plug hard drive fan Reverse steps 1 through 5 to replace a hot-plug drive fan.