3-8 Compaq ProLiant ML530 Servers Maintenance and Service Guide Error Code A Critical Error occurred prior to this power-up Unsupported Processor Detected System Halted FATAL ROM ERROR: The System ROM is not properly programmed 101-ROM Error 101-I/O ROM Error 102-System Board Failure 104-ASR-2 Timer Failure 105-Current System ROM is corrupt - now booting redundant System ROM 162-System Options Not Set 163-Time & Date Not Set 164-Memory Size Error 172-Configuration Nonvolatile Memory Invalid 173-Slot ID Mismatch Table 3-2 POST Error Messages Audible Beeps None 1 long, 1 short Probable Source of Problem A catastrophic system error, which caused the server to crash, has been logged. Processor not supported by current system ROM. 1 long, 1 short ROM programmed in the factory incorrectly. Recommended Action Run Diagnostics. Replace the failed assembly as indicated. Check documentation for supported processors, and if supported, remove the processor and update the system to the latest ROM. Then reinstall the processor. Flash the ROM or replace the physical ROM part. 1 long, 1 short None None System ROM checksum Options ROM checksum DMA, timers, and so on None 2 long System board failure Nonbooted ROM image is corrupt. Run Diagnostics. Replace the failed assembly as indicated. Run Diagnostics. Replace the failed assembly as indicated. Replace the system board. Run the Compaq System Configuration Utility. Run Diagnostics. Replace the failed assembly as indicated. Flash the ROM utilizing ROMPaq. 2 short 2 short 2 short None None Configuration incorrect Invalid time or date in configuration memory Configuration memory incorrect Nonvolatile configuration corrupt or jumper installed. Run the System Configuration Utility and correct the configuration. Run the System Configuration Utility and correct the time or date. Run the System Configuration Utility and correct memory configuration. Run the System Configuration Utility and correct. Board replaced, configuration not updated. Run the System Configuration Utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

3-8
Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
A Critical Error
occurred prior to this
power-up
None
A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace the
failed assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short
Processor not supported by
current system ROM.
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to the latest ROM. Then
reinstall the processor.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short
ROM programmed in the factory
incorrectly.
Flash the ROM or replace the
physical ROM part.
101-ROM Error
1 long, 1 short
System ROM checksum
Run Diagnostics. Replace the
failed assembly as indicated.
101-I/O ROM Error
None
Options ROM checksum
Run Diagnostics. Replace the
failed assembly as indicated.
102-System Board
Failure
None
DMA, timers, and so on
Replace the system board. Run
the Compaq System
Configuration Utility.
104-ASR-2 Timer
Failure
None
System board failure
Run Diagnostics. Replace the
failed assembly as indicated.
105-Current System
ROM is corrupt
now booting
redundant System
ROM
2 long
Nonbooted ROM image is
corrupt.
Flash the ROM utilizing
ROMPaq.
162-System Options
Not Set
2 short
Configuration incorrect
Run the System Configuration
Utility and correct the
configuration.
163-Time & Date Not
Set
2 short
Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct the time or
date.
164-Memory Size
Error
2 short
Configuration memory incorrect
Run the System Configuration
Utility and correct memory
configuration.
172-Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration corrupt
or jumper installed.
Run the System Configuration
Utility and correct.
173-Slot ID
Mismatch
None
Board replaced, configuration not
updated.
Run the System Configuration
Utility and correct.
continued