Compaq ML530R Service Guide - Page 75

with the Memory Address Range of an ISA Card. Check the Memory Address

Page 75 highlights

Diagnostics and Troubleshooting 3-15 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1764-Slot X Drive Array - Capacity Expansion Process is temporarily disabled (followed by one of the following): Expansion will resume when Array Accelerator has been reattached. Expansion will resume when Array Accelerator has been replaced. Expansion will resume when Array Accelerator RAM allocation is successful. Expansion will resume when Array Accelerator battery reaches full charge. Expansion will resume when automatic data recovery has been completed. 1765-Slot X Drive Array Option ROM Appears to Conflict with an ISA Card. ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with the SMART-2/E 8-bit Option ROM due to EISA bus limitations. Please remove or reconfigure the ISA card. 1766-Slot X Drive Array requires System ROM Upgrade. Run Systems ROMPaq Utility. 1767-Slot X Drive Array Option ROM is Not Programmed Correctly or may Conflict with the Memory Address Range of an ISA Card. Check the Memory Address Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt SMART-2/E Option ROM Reprogramming. 1768-Slot X Drive Array-Resuming logical drive expansion process. 1769-Slot X Drive Array - Drive(s) disabled due to failure during expand. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives. 1771-Primary Disk Port Address Assignment Conflict None SMART-2 Controller error None SMART-2 Controller error. Data has been lost while expanding the array; therefore, the drives have been temporarily disabled. None Address assignment conflict. Internal and external hard drive controllers are both assigned to the primary address. Recommended Action Reattach or replace the array accelerator. Wait until the array accelerator batteries to fully charge or for Automatic Data Recovery to complete, as indicated. Remove or reconfigure conflicting ISA cards. Disable "shared memory" on any ISA network cards that may be installed. Run the latest Systems ROMPaq Utility to upgrade the System ROMs. Remove or reconfigure conflicting ISA cards, especially any cards that are not recognized by the System Configuration Utility. Try reprogramming the ROM on the SMART-2/E Controller using the latest Options ROMPaq (version 2.29 or later). No action required. Message displays whenever a controller reset or power cycle occurs while an array expansion is in progress. Press F2 to accept the data loss and re-enable the logical drives. Restore data from backup. Run the System Configuration Utility and correct. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Diagnostics and Troubleshooting
3-15
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1764-Slot
X
Drive Array
Capacity Expansion Process is temporarily disabled
(followed by one of the following):
Expansion will resume when Array Accelerator has been reattached.
Expansion will resume when Array Accelerator has been replaced.
Expansion will resume when Array Accelerator RAM allocation is successful.
Expansion will resume when Array Accelerator battery reaches full charge.
Expansion will resume when automatic data recovery has been completed.
Reattach or replace the array
accelerator. Wait until the array
accelerator batteries to fully
charge or for Automatic Data
Recovery to complete, as
indicated.
1765-Slot
X
Drive Array Option ROM Appears to Conflict with an ISA Card. ISA
cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF
along with the SMART-2/E 8-bit Option ROM due to EISA bus limitations. Please
remove or reconfigure the ISA card.
Remove or reconfigure
conflicting ISA cards.
Disable
shared memory
on any ISA network cards
that may be installed.
1766-Slot
X
Drive Array requires System ROM Upgrade. Run Systems ROMPaq
Utility.
Run the latest Systems ROMPaq
Utility to upgrade the System
ROMs.
1767-Slot
X
Drive Array Option ROM is Not Programmed Correctly or may Conflict
with the Memory Address Range of an ISA Card. Check the Memory Address
Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.
Remove or reconfigure
conflicting ISA cards, especially
any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the ROM on the
SMART-2/E Controller using the
latest Options ROMPaq
(version 2.29 or later).
1768-Slot
X
Drive
Array-Resuming
logical drive
expansion process.
None
SMART-2 Controller error
No action required. Message
displays whenever a controller
reset or power cycle occurs
while an array expansion is in
progress.
1769-Slot
X
Drive
Array
Drive(s)
disabled due to
failure during
expand. Select
F1 to
continue with logical
drives disabled.
Select F2 to accept
data loss and to
re-enable logical
drives.
None
SMART-2 Controller error. Data
has been lost while expanding
the array; therefore, the drives
have been temporarily disabled.
Press
F2
to accept the data loss
and re-enable the logical drives.
Restore data from backup.
1771-Primary Disk
Port Address
Assignment Conflict
None
Address assignment conflict.
Internal and external hard drive
controllers are both assigned to
the primary address.
Run the System Configuration
Utility and correct.
continued