Compaq ProLiant 6400R Microsoft Windows Event ID and SNMP Traps Reference Guid - Page 101

NT Event ID: 1135 Hex0x8435046f cpqsvmsg.dll

Page 101 highlights

• cpqHoTrapFlags • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: "Temperature Exceeded on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]." NT Event ID: 1135 (Hex)0x8435046f (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: A Temperature Sensor Condition has been set to degraded. The system may or may not shut down depending on the state of the thermal degraded action value '%6'. SNMP Trap: cpqHe3TemperatureDegraded - 6041 in CPQHLTH.MIB Symptom: The temperature status has been set to degraded in the specified chassis and location. The server's temperature is outside of the normal operating range. The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3). Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeThermalDegradedAction • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: "Temperature out of range on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]. Shutdown may occur." NT Event ID: 1136 (Hex)0x44350470 (cpqsvmsg.dll) Log Severity: Information (1) Log Message: A Temperature Sensor Condition has been set to OK. The system's temperature has returned to the normal operating range. SNMP Trap: cpqHe3TemperatureOk - 6042 in CPQHLTH.MIB Symptom: The temperature status has been set to OK in the specified chassis and location. The server's temperature has returned to the normal operating range. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: "Temperature Normal on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]." NT Event ID: 1137 (Hex)0x84350471 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: The DC-DC power converter is in a degraded state. Replace the power converter. SNMP Trap: cpqHe3PowerConverterDegraded - 6043 in CPQHLTH.MIB Server agents 101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

Server agents 101
cpqHoTrapFlags
cpqHeTemperatureChassis
cpqHeTemperatureLocale
Supporting SNMP Trap Description: “Temperature Exceeded on Chassis [cpqHeTemperatureChassis],
Location [cpqHeTemperatureLocale].”
NT Event ID: 1135 (Hex)0x8435046f (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A Temperature Sensor Condition has been set to degraded. The system may or may
not shut down depending on the state of the thermal degraded action value '%6'.
SNMP Trap: cpqHe3TemperatureDegraded - 6041 in CPQHLTH.MIB
Symptom: The temperature status has been set to degraded in the specified chassis and location. The
server's temperature is outside of the normal operating range. The server is shut down if the
cpqHeThermalDegradedAction variable is set to shutdown (3).
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeThermalDegradedAction
cpqHeTemperatureChassis
cpqHeTemperatureLocale
Supporting SNMP Trap Description: “Temperature out of range on Chassis
[cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]. Shutdown may occur.”
NT Event ID: 1136 (Hex)0x44350470 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: A Temperature Sensor Condition has been set to OK. The system's temperature has
returned to the normal operating range.
SNMP Trap: cpqHe3TemperatureOk - 6042 in CPQHLTH.MIB
Symptom: The temperature status has been set to OK in the specified chassis and location. The
server's temperature has returned to the normal operating range.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeTemperatureChassis
cpqHeTemperatureLocale
Supporting SNMP Trap Description: “Temperature Normal on Chassis [cpqHeTemperatureChassis],
Location [cpqHeTemperatureLocale].”
NT Event ID: 1137 (Hex)0x84350471 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The DC-DC power converter is in a degraded state. Replace the power converter.
SNMP Trap: cpqHe3PowerConverterDegraded - 6043 in CPQHLTH.MIB