Compaq ProLiant 6400R Microsoft Windows Event ID and SNMP Traps Reference Guid - Page 44

Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected

Page 44 highlights

• cpqSsChassisName • cpqSsChassisTime • cpqFcaAccelBoxIoSlot • cpqFcaAccelStatus • cpqFcaCntlrModel • cpqFcaAccelSerialNumber • cpqFcaAccelTotalMemory • cpqFcaAccelErrCode Supporting SNMP Trap Description: "Status is now [cpqFcaAccelStatus]." NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll) Log Severity: Error (3) Event Title: External Array Accelerator Bad Data. Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array "%4" is reporting that it contains bad cached data. SNMP Trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected an Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaAccelBoxIoSlot • cpqFcaCntlrModel • cpqFcaAccelSerialNumber • cpqFcaAccelTotalMemory Supporting SNMP Trap Description: "Accelerator lost battery power. Data Loss possible." NT Event ID: 1150 (Hex)0xc435047e (cpqstmsg.dll) Log Severity: Error (3) Event Title: External Array Accelerator Battery Failed. Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array "%4" is reporting a battery failure. SNMP Trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB Symptom: External Array Accelerator Board Battery failed. This trap indicates that the agent has detected a battery failure associated with the Array Accelerator Cache Board. User Action: Replace the Accelerator Cache Board. Supporting SNMP Trap Data: • sysName Storage agents 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

Storage agents 44
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaAccelStatus
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
cpqFcaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqFcaAccelStatus].”
NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array
“%4” is reporting that it contains bad cached data.
SNMP Trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB
Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected
an Array Accelerator Cache Board that has lost battery power. If data was being stored in the
accelerator memory when the system lost power, that data has been lost.
User Action: Verify that no data has been lost.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”
NT Event ID: 1150 (Hex)0xc435047e (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Battery Failed.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array
“%4” is reporting a battery failure.
SNMP Trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB
Symptom: External Array Accelerator Board Battery failed. This trap indicates that the agent has
detected a battery failure associated with the Array Accelerator Cache Board.
User Action: Replace the Accelerator Cache Board.
Supporting SNMP Trap Data:
sysName