Compaq ProLiant 6400R Microsoft Windows Event ID and SNMP Traps Reference Guid - Page 69

Event Title: Drive Array Tape Drive Status Change.

Page 69 highlights

• cpqDaTapeLibraryModel • cpqDaTapeLibraryFWRev • cpqDaTapeLibrarySerialNumber • cpqDaTapeLibraryDoorStatus Supporting SNMP Trap Description: "The door is [cpqDaTapeLibraryDoorStatus] for tape library." NT Event ID: 1209 (Hex)0x843504b9 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Status Change. Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 has a new status of %7. SNMP Trap: cpqDa6TapeDriveStatusChange - 3043 in CPQIDA.MIB Symptom: Tape Drive Status Change. This trap indicates that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive. User Action: If the tape is failed, check the tape and all SCSI connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex • cpqDaTapeDrvName • cpqDaTapeDrvFwRev • cpqDaTapeDrvSerialNumber • cpqDaTapeDrvStatus Supporting SNMP Trap Description: "Status is now [cpqDaTapeDrvStatus] for a tape drive." NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Cleaning Required. Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 requires cleaning. SNMP Trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeDrvCntlrIndex Storage agents 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

Storage agents 69
cpqDaTapeLibraryModel
cpqDaTapeLibraryFWRev
cpqDaTapeLibrarySerialNumber
cpqDaTapeLibraryDoorStatus
Supporting SNMP Trap Description: “The door is [cpqDaTapeLibraryDoorStatus] for tape library.”
NT Event ID: 1209 (Hex)0x843504b9 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Status Change.
Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 has a new status of %7.
SNMP Trap: cpqDa6TapeDriveStatusChange - 3043 in CPQIDA.MIB
Symptom: Tape Drive Status Change. This trap indicates that the agent has detected a change in the
status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable
cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive.
User Action: If the tape is failed, check the tape and all SCSI connections.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex
cpqDaTapeDrvBusIndex
cpqDaTapeDrvScsiIdIndex
cpqDaTapeDrvLunIndex
cpqDaTapeDrvName
cpqDaTapeDrvFwRev
cpqDaTapeDrvSerialNumber
cpqDaTapeDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqDaTapeDrvStatus] for a tape drive.”
NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Cleaning Required.
Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 requires cleaning.
SNMP Trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have
a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex