Compaq ProLiant 6400R Microsoft Windows Event ID and SNMP Traps Reference Guid - Page 136

NT Event ID: 1290 Hex0x4435050A cpqnimsg.dll, SNMP Trap: cpqNic3ConnectivityLost - 18012 in CPQNIC.MIB

Page 136 highlights

• cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqNicIfLogMapAdapterOKCount Supporting SNMP Trap Description: "Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." NT Event ID: 1290 (Hex)0x4435050A (cpqnimsg.dll) Log Severity: Information (1) Log Message: Connectivity has been restored for the NIC in slot %1, port %2. SNMP Trap: cpqNic3ConnectivityRestored - 18011 in CPQNIC.MIB Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cpqSePciSlotBoardName • cpqNicIfPhysAdapterPartNumber • ipAdEntAddr • cpqNicIfLogMapIPV6Address Supporting SNMP Trap Description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." NT Event ID: 1291 (Hex)0xc435050B (cpqnimsg.dll) Log Severity: Error (3) Log Message: Connectivity has been lost for the NIC in slot %1, port %2. SNMP Trap: cpqNic3ConnectivityLost - 18012 in CPQNIC.MIB Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 136

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

NIC agents 136
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: “Redundancy decreased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1290 (Hex)0x4435050A (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Connectivity has been restored for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityRestored - 18011 in CPQNIC.MIB
Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the
physical adapter in a single adapter configuration returns to the OK condition or at least one physical
adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of
a faulty cable or re-attaching a cable that was unplugged.
User Action: None required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP Trap Description: “Connectivity is restored for adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1291 (Hex)0xc435050B (cpqnimsg.dll)
Log Severity: Error (3)
Log Message: Connectivity has been lost for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityLost - 18012 in CPQNIC.MIB
Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition.
This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a
redundant configuration fails. This can be caused by loss of link due to a cable being removed from
the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this
condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found,
the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
sysName