Hardware Monitor Settings, Applies to HWMMem_AlertLevel
View all D-Link DFL-800-AV-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 334 highlights
13.17. Hardware Monitor Settings Chapter 13. Advanced Settings 13.17. Hardware Monitor Settings HWM_PollInterval Polling intervall for Hardware Monitor which is the delay in milliseconds between reading of hardware monitor values. Minimum 100, Maximum 10000. Default: 500 ms HWMMem_Interval Memory polling interval which is the delay in minutes between reading of memory values. Minimum 1, Maximum 200. Default: 15 mins HWMMem_LogRepetition Should we send a log message for each poll result that is in the Alert, Critical or Warning level, or should we only send when a new level is reached. If True, a message is sent each time HWMMem_Interval is triggered If False, a message is sent when a value goes from one level to another. Default: False HWMMem_UsePercent True if the memory monitor uses a percentage as the unit for monitoring, False if it uses Megabyte. Applies to HWMMem_AlertLevel, HWMMem_CriticalLevel and HWMMem_WarningLevel. Default: True HWMMem_AlertLevel Generate an Alert log message if free memory is below this value. Disable by setting to 0. Maximum value is 10,000. Default: 0 HWMMem_CriticalLevel Generate a Critical log message if free memory is below this value. Disable by setting to 0. Maximum value is 10,000. Default: 0 HWMMem_WarningLevel Generate a Warning log message if free memory is below this value. Disable by setting to 0. Maximum value 10,000. Default: 0 334