Dell DR4300 DR Series System Administrator Guide - Page 162

System Event Message, please re-apply the licenses and reboot.

Page 162 highlights

System Event Message Description/Meaning or Action Datacheck detected potential corrupt lsu info. Run filesystem scan as soon as possible. ("maintenance -filesystem --start_scan verify_rda_metadata") Temperature warning detected on NVRAM PCI controller. Please check the data center air conditioning, rack ventilation, and internal cooling fans for any issues. Ensure that there is proper air flow through the system appliance, and clean the system cooling vents as needed. If issue persists, contact Dell Support for assistance or intervention. Filesystem Name Space partition has reached its maximum allowable limit. Please delete any old, unused file(s) or disable replication(s). If issue persists, contact Dell Support for assistance or intervention. Filesystem Name Space partition is reaching its maximum allowable limit. New replication resynch(s) will be stopped. If issue persists, contact Dell Support for assistance or intervention. One or more software package is incompatible. Please upgrade the appliance to rectify the issue. Filesystem volume has become in-active. Please contact Dell Support for assistance or intervention. Filesystem server response time exceeded max threshold. Informational message. No user intervention is required. The memory capacity of the storage appliance is below the minimum required for correct operation. The storage appliance requires service. An OST container quota is exceeded. Check the event for container details. One of the storage enclosure has become offline. Please power-down the appliance and rectify the issue. One or more storage enclosure(s) are missing/offline. Please check whether the storage enclosure(s) are poweredup and connected to the appliance. Storage enclosure license(s) are missing. If Restore Manager (RM) recovery was performed recently, please re-apply the license(s) and reboot. System has a huge backlog of book keeping work. Informational message. No user intervention is required. Filesystem cleaner will be enabled outside of schedule setting and performance impact will be observed. System clock has drifted more than 24 hours, from the Please check your clock settings and reboot. last filesystem start. Replication is disconnected on one or more containers. Please check event log or replication stats for details. One or more replication target systems are running low in space. Please check event log or replication stats for details. Filesystem scan completed with no inconsistencies. Switching back to operational mode. Informational message. No user intervention is required. Replication detected potential inconsistency. Run filesystem scan with data verification check as soon as possible. ("maintenance --filesystem --start_scan verify_data") Seeding device became full. Add new seeding device to continue. 162

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

System Event Message
Description/Meaning or Action
Datacheck detected potential corrupt lsu info.
Run filesystem scan as soon as possible. ("maintenance --
filesystem --start_scan verify_rda_metadata")
Temperature warning detected on NVRAM PCI
controller.
Please check the data center air conditioning, rack
ventilation, and internal cooling fans for any issues. Ensure
that there is proper air flow through the system appliance,
and clean the system cooling vents as needed. If issue
persists, contact Dell Support for assistance or intervention.
Filesystem Name Space partition has reached its
maximum allowable limit.
Please delete any old, unused file(s) or disable replication(s).
If issue persists, contact Dell Support for assistance or
intervention.
Filesystem Name Space partition is reaching its
maximum allowable limit.
New replication resynch(s) will be stopped. If issue persists,
contact Dell Support for assistance or intervention.
One or more software package is incompatible.
Please upgrade the appliance to rectify the issue.
Filesystem volume has become in-active.
Please contact Dell Support for assistance or intervention.
Filesystem server response time exceeded max
threshold.
Informational message. No user intervention is required.
The memory capacity of the storage appliance is
below the minimum required for correct operation. The
storage appliance requires service.
An OST container quota is exceeded.
Check the event for container details.
One of the storage enclosure has become offline.
Please power-down the appliance and rectify the issue.
One or more storage enclosure(s) are missing/offline.
Please check whether the storage enclosure(s) are powered-
up and connected to the appliance.
Storage enclosure license(s) are missing.
If Restore Manager (RM) recovery was performed recently,
please re-apply the license(s) and reboot.
System has a huge backlog of book keeping work.
Filesystem cleaner will be enabled outside of schedule
setting and performance impact will be observed.
Informational message. No user intervention is required.
System clock has drifted more than 24 hours, from the
last filesystem start.
Please check your clock settings and reboot.
Replication is disconnected on one or more
containers.
Please check event log or replication stats for details.
One or more replication target systems are running
low in space.
Please check event log or replication stats for details.
Filesystem scan completed with no inconsistencies.
Switching back to operational mode.
Informational message. No user intervention is required.
Replication detected potential inconsistency.
Run filesystem scan with data verification check as soon as
possible. ("maintenance --filesystem --start_scan
verify_data")
Seeding device became full.
Add new seeding device to continue.
162