Dell PowerEdge T100 Hardware Owner's Manual - Page 26
Warning! No micro, See Getting Help - system setup
View all Dell PowerEdge T100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions Time-of-day clock Faulty battery; faulty stopped system board. See "Troubleshooting the System Battery" on page 112. If the problem persists, see "Getting Help" on page 139. Time-of-day not set Incorrect Time or Date - please run SETUP settings; faulty system program battery. Check the Time and Date settings. See "Using the System Setup Program" on page 29. If the problem persists, see "Troubleshooting the System Battery" on page 112. Timer chip counter Faulty system board. 2 failed See "Getting Help" on page 139. Unexpected interrupt in protected mode Faulty or improperly installed memory modules or faulty system board. Ensure that all memory modules are properly installed. See "Memory Module Installation Guidelines" on page 75. If the problem persists, see "Troubleshooting System Memory" on page 115. If the problem persists, see "Getting Help" on page 139. Utility partition not available Utility partition is not available on the hard disk Create a utility partition on the boot hard drive. See the CDs that came with your system. Warning! No micro code update loaded for processor 0 Micro code update failed. Update the BIOS firmware. See "Getting Help" on page 139. 26 About Your System