Dell XPS 430 Quick Reference Guide - Page 29
Date Not Set, CMOS Memory Size - cmos battery
View all Dell XPS 430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Message CMOS Battery State Low CMOS Checksum Failure CMOS System Options Not Set CMOS Display Type Mismatch CMOS Memory Size Mismatch CMOS Time and Date Not Set Diskette Boot Failure DMA Error DMA 1 Error DMA 2 Error HDD Controller Failure Possible Cause The system configuration information in the system setup program is incorrect or the battery charge may be low. Corrective Action Enter the system setup program (see the Service Manual on the Dell Support website at support.dell.com), verify the system configuration, and then restart the computer. Drive A or B is present but has failed the BIOS POST. Error in the DMA controller on the system board. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program (see the Service Manual on the Dell Support website at support.dell.com). Check the interface cable at both ends. The keyboard or system board may need to be replaced. The BIOS cannot communicate with the hard drive controller. Ensure that the hard drive is installed correctly in the computer and defined correctly in the system setup program (see the Service Manual on the Dell Support website at support.dell.com). Check the interface cable at both ends. Troubleshooting 29