Dewalt D55167 Instruction Manual - Page 9

Save These Instructions, For Future Use, Features Fig. 1 - motor

Page 9 highlights

English SAVE THESE INSTRUCTIONS FOR FUTURE USE Features (Fig. 1) Auto/Off Switch Place this switch (A) in the AUTO (I) position to provide automatic power to the pressure switch and OFF (O) A to remove power at the end of each use. Pressure Switch I f The pressure switch (I) automatically starts the motor when the air tank pressure drops below the factory set cut-in pressure. It stops the motor when the air tank pressure reaches the factory set cut‑out pressure. Safety Valve If the pressure switch does not D shut off the air compressor at its B cut-out pressure setting, the safety valve (G) will protect against high C pressure by popping out at its factory set pressure (slightly higher E than the pressure switch cut-out setting). G Check Valve When the air compressor is operating, the check valve (F) is open, allowing compressed air to enter the air tank. When the air compressor reaches cut-out pressure, the check valve closes, allowing air pressure to remain inside the air tank. Tank Pressure Gauge The tank pressure gauge (B) indicates the reserve air pressure in the tank. regulated Pressure Gauge The outlet pressure gauge (C) indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure. Regulator The regulator (D) controls the air pressure shown on the regulated pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place. DRAIN TANK DAILY Universal Quick Connect BodY The universal quick connect body (E) accepts the three most popular styles of quick connect plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes connections simple and easy. Drain Valve The drain valve (H) is located at the base of the air tank and is used to drain condensation at the end of each use. See Draining Air Tank under Maintenance. Cooling System H This compressor contains an advanced design cooling system. It is normal for this fan to blow air through the vent holes in large amounts. The cooling system is working when air is expelled. Air Compressor Pump The pump compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

9
English
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
FEATURES (FIG. 1)
AUTO/OFF SWITCH
Place this switch (A) in the AUTO (I)
F
A
I
position to provide automatic power
to the pressure switch and OFF (O)
to remove power at the end of each
use.
PRESSURE SWITCH
The pressure switch (I) automatically starts the motor when the
air tank pressure drops below the factory set
cut-in
pressure. It
stops the motor when the air tank pressure reaches the factory set
cut-out
pressure.
SAFETY VALVE
If the pressure switch does not
C
D
B
G
E
shut off the air compressor at its
cut-out pressure setting, the safety
valve (G) will protect against high
pressure by popping out at its
factory set pressure (slightly higher
than the pressure switch cut-out
setting).
CHECK VALVE
When the air compressor is operating, the check valve (F) is
open, allowing compressed air to enter the air tank. When the
air compressor reaches cut-out pressure, the check valve closes,
allowing air pressure to remain inside the air tank.
TANK PRESSURE GAUGE
The tank pressure gauge (B) indicates the reserve air pressure in
the tank.
REGULATED PRESSURE GAUGE
The outlet pressure gauge (C) indicates the air pressure available
at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure.
REGULATOR
The regulator (D) controls the air pressure shown on the regulated
pressure gauge. Pull the knob out and turn clockwise to increase
pressure and counterclockwise to decrease pressure. When the
desired pressure is reached push knob in to lock in place.
UNIVERSAL QUICK CONNECT BODY
The universal quick connect body (E) accepts the three most
popular styles of quick connect plugs: Industrial, automotive, and
ARO. One hand push-to-connect operation makes connections
simple and easy.
DRAIN VALVE
The drain valve (H) is located at the base of the air
H
tank and is used to drain condensation at the end
of each use.
See
Draining Air Tank
under
Maintenance.
COOLING SYSTEM
This compressor contains an advanced design cooling system.
It is normal for this fan to blow air through the vent holes in large
amounts. The cooling system is working when air is expelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not
available until the compressor has raised the air tank pressure
above that required at the air outlet.