Fixed problems Fixed problems This section identifies issues fixed in various releases. Visit the EMC Powerlink® Issue Tracker website at http://Powerlink.EMC.com for the most recent updates and information on previous AX100 Integrated Management Software releases. Hardware problems fixed in version 02.19.100.5.043 Problem AX100SC, AX100SCi, AX100, AX100i - Read cache is not enabled when the storage system enables the system write cache (135473). AX100SC, AX100SCi, AX100, AX100i - In very infrequent cases heavy I/O to the same LBA causes the front-end ports to hang (154617). AX100, AX100i - System Fault LED does not light when the UPS serial cable is disconnected (156802). AX100SC, AX100SCi - System Fault LED does not light when the wrong cache card (from another storage system) is installed in a storage system (156803). AX100SC, AX100SCi, AX100, AX100i - Sniff verify is disabled (163178). AX100SCi, AX100i - iSCSI cluster and congestion issues caused performance problems(159238 & 159278). Details Fixed in version: 02.19.100.5. 043 Solution: Storage system now consistently enables the read cache when it enables system cache. Fixed in version: 02.19.100.5. 043 Solution: Prevents overlapped I/O from reaching FLARE, which prevents the front-end ports from hanging. Fixed in version: 02.19.100.5. 043 Solution: Fixed the System Fault LED so that it will light when the UPS serial cable is not connected. Fixed in version: 02.19.100.5. 043 Solution: Fixed the System Fault LED to light when the wrong cache card is installed. Fixed in version: 02.19.100.5. 043 Solution: Sniff verify is now enabled. Fixed in version: 02.19.100.5. 043 Solution: Fixed iSCSI cluster and congestion issues. Hardware problems fixed in version 02.19.100.5.041 Problem AX100SC, AX100SCi - Heavy host I/O to the storage system causes a cache resource problem, which causes the storage system to panic. (142940). AX100SC, AX100SCi, AX100, AX100i - When Solaris clustered hosts attempt to trespass a double-faulted LUN, the storage system returns an event (reservation conflict) to the cluster that causes the storage system to panic (139699). Details Fixed in version: 02.19.100.5. 041 Solution: Optimized cache resource allocation to accommodate heavy I/O and prevent an SP panic. Fixed in version: 02.19.100.5. 041 Solution: FLARE now returns the proper error to the host when the condition described occurs. 10 EMC AX100-Series Integrated Management Software Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

10
Fixed problems
EMC AX100-Series Integrated Management Software Release Notes
Fixed problems
This section identifies issues fixed in various releases.
Visit the EMC Powerlink
®
Issue Tracker website at
for the most recent updates and
information on previous AX100 Integrated Management Software
releases.
Hardware problems fixed in version 02.19.100.5.043
Problem
Details
AX100SC, AX100SCi, AX100, AX100i –
Read
cache is not enabled when the storage system
enables the system write cache (135473).
Fixed in version
: 02.19.100.5. 043
Solution
:
Storage system now consistently enables the
read cache when it enables system cache.
AX100SC, AX100SCi, AX100, AX100i –
In very
infrequent cases heavy I/O to the same LBA
causes the front-end ports to hang (154617).
Fixed in version
: 02.19.100.5. 043
Solution
: Prevents overlapped I/O from reaching FLARE,
which prevents the front-end ports from hanging.
AX100, AX100i –
System Fault LED does not light
when the UPS serial cable is disconnected
(156802).
Fixed in version
: 02.19.100.5. 043
Solution
: Fixed the System Fault LED so that it will light
when the UPS serial cable is not connected.
AX100SC, AX100SCi –
System Fault LED does
not light when the wrong cache card (from another
storage system) is installed in a storage system
(156803).
Fixed in version
: 02.19.100.5. 043
Solution
: Fixed the System Fault LED to light when the
wrong cache card is installed.
AX100SC, AX100SCi, AX100, AX100i –
Sniff
verify is disabled (163178).
Fixed in version
: 02.19.100.5. 043
Solution
:
Sniff verify is now enabled.
AX100SCi, AX100i –
iSCSI cluster and
congestion issues caused performance
problems(159238 & 159278).
Fixed in version
: 02.19.100.5. 043
Solution
: Fixed iSCSI cluster and congestion issues.
Hardware problems fixed in version 02.19.100.5.041
Problem
Details
AX100SC, AX100SCi –
Heavy host I/O to the
storage system causes a cache resource problem,
which causes the storage system to panic.
(142940).
Fixed in version
: 02.19.100.5. 041
Solution
: Optimized cache resource allocation to
accommodate heavy I/O and prevent an SP panic.
AX100SC, AX100SCi, AX100, AX100i –
When
Solaris clustered hosts attempt to trespass a
double-faulted LUN, the storage system returns an
event (reservation conflict) to the cluster that
causes the storage system to panic (139699).
Fixed in version
: 02.19.100.5. 041
Solution
: FLARE now returns the proper error to the host
when the condition described occurs.