30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS (Model with Electric Oven and Gas Cooktop) WALL 35 7/8" Min. (91.1 cm Min.) C B WALL If there is a wall: 9" Min. (22.9 cm Min) Left side See note 18" Min. (45.7 cm Min.) 13" Max. (33 cm Max.) D G F If there is a wall: 9" Min. (22.9 cm Min.) Right side A E Grounded Wall Outlet or junction box NOTE: 28" (71.1 cm) minimum clearance between the cooktop and the bottom of the cabinet when the bottom location 24" Min. of wood or metal cabinet is protected by not less than (61 cm Min.) 1/4" (0.64 cm) flame retardant millboard covered with 24 1/2" Max. (62.2 cm Max.) not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) Do not pinch the power supply cord between the range and the wall. stainless steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper. 34" (86.4 cm) minimum clearance when the cabinet is Do not seal the range to the side cabinets. unprotected. Figure 2 - 36" Range (30" Range, see page 1) A. HEIGHT B. WIDTH 41 5/8" (105.7 cm) Min. 35 7/8" 42 5/8" (108.3 cm) Max. (91.1 cm) C. DEPTH TO FRONT D. HEIGHT OF COOKTOP OF RANGE 27 ½" 35 3/4" (90.8 cm) Min. (69.9 cm) 36 3/4" (93.3 cm) Max. E. DEPTH WITH DOOR OPEN 47 3/8" (120.3 cm) F. HEIGHT OF COUNTERTOP 36" (91.4 cm) Standard 35 3/4" (90.8 cm) Min. G. MINIMUM CUTOUT WIDTH 36 1/16" (91.6 cm) Important Notes to the Installer 1. Read all instructions contained in these installation instructions before installing range. 2. Remove all packing material from the oven compartments before connecting the electrical supply to the range. 3. Observe all governing codes and ordinances. 4. Be sure to leave these instructions with the consumer. 5. Note: For operation at 2000 ft. elevations above see level, appliance rating shall be reduced by 4 percent for each additional 1000 ft. Important Note to the Consumer Keep these instructions with your owner's guide for future reference. Optional Items Available: • A Cooktop Trim, if you want to remove the actual 6" Stainless Steel Backsplash. • A 9" (22.9 cm) Stainless Steel Backsplash • A 12" (30.5 cm) Stainless Steel Backsplash Those kits can be ordered for purchase through an Electrolux Service Center at 1-877-4ELECTROLUX (1-877435-3287). IMPORTANT SAFETY INSTRUCTIONS Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1-latest edition. When installing in a manufactured (mobile) home, installation must conform with Manufactured Home Construction and Safety Standard, title 24CFR, part 3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI Z225.1/NFPA 501A-latest edition, or with CAN/CSA-Z240 MH, or with local codes . This range has been design certified by CSA international. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find them in the Use and Care Guide, read it carefully. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

2
30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
(Model with Electric Oven and Gas Cooktop)
Important Notes to the Installer
1.
Read all instructions contained in these installation
instructions before installing range.
2.
Remove all packing material from the oven
compartments before connecting the electrical supply
to the range.
3.
Observe all governing codes and ordinances.
4.
Be sure to leave these instructions with the consumer.
5.
Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each
additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your owner's guide for future
reference.
Optional Items Available:
A Cooktop Trim, if you want to remove the actual 6"
Stainless Steel Backsplash.
A 9" (22.9 cm) Stainless Steel Backsplash
A 12" (30.5 cm) Stainless Steel Backsplash
Those kits can be ordered for purchase through an
Electrolux Service Center at 1-877-4ELECTROLUX (1-877-
435-3287).
NOTE:
28" (71.1 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet is protected by not less than
1/4" (0.64 cm) flame retardant millboard covered with
not less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum, or 0.020"
(0.5 mm) copper.
34" (86.4 cm) minimum clearance when the cabinet is
unprotected.
Do not pinch the power supply cord between the range
and the wall.
Do not seal the range to the side cabinets.
A
B
C
D
E
G
F
13" Max.
(33 cm Max.)
24" Min.
(61 cm Min.)
24 1/2" Max.
(62.2 cm Max.)
35 7/8" Min.
(91.1 cm Min.)
See
note
Grounded
Wall Outlet or
junction box
location
WALL
WALL
If there is a wall:
9" Min.
(22.9 cm Min)
Left side
18" Min.
(45.7 cm Min.)
If there is a wall:
9" Min.
(22.9 cm Min.)
Right side
A.
HEIGHT
41 5/8" (105.7 cm) Min.
42 5/8" (108.3 cm) Max.
B.
WIDTH
35 7/8"
(91.1 cm)
C.
DEPTH TO FRONT
OF RANGE
27 ½"
(69.9 cm)
D.
HEIGHT OF COOKTOP
35 3/4" (90.8 cm) Min.
36 3/4" (93.3 cm) Max.
E.
DEPTH WITH
DOOR OPEN
47 3/8"
(120.3 cm)
F.
HEIGHT OF
COUNTERTOP
36" (91.4 cm) Standard
35 3/4" (90.8 cm) Min.
G.
MINIMUM
CUTOUT WIDTH
36 1/16"
(91.6 cm)
Figure 2 - 36" Range (30" Range, see page 1)
IMPORTANT SAFETY
INSTRUCTIONS
Installation of this range must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1—latest edition.
When installing in a manufactured (mobile) home,
installation must conform with Manufactured Home
Construction and Safety Standard, title 24CFR, part
3280 [Formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD (part 280)] or,
when such standard is not applicable, the Standard for
Manufactured Home Installation, ANSI Z225.1/NFPA
501A-latest edition, or with CAN/CSA-Z240 MH, or with
local codes .
This range has been design certified by CSA
international. As with any appliance using gas and
generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care