Fisher and Paykel DD24STI7 BOOK INSTL DD24S PH7 US CA EN (English) - Page 10
Cavity Preparation
View all Fisher and Paykel DD24STI7 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
8 CAVITY PREPARATION COUNTERTOP These marks indicate formed bracket screw locations, if securing by drawer removal. If there is no side partition, you can construct timber bracing as something to secure into. Moisture 3⁄8" (10mm) protection tape must be applied. Important! The power outlet must be located in a cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A Important! Adjacent cabinetry must not extend above cavity base Services can be located either side of the dishwasher. ø max. 1½"(38 mm) max. 17 11⁄16" (450 mm) Services hole Can be located either side of dishwasher, preferably at the bottom of the cavity, as shown. If adequate clearance, services hole can be made higher to clear toekick space. If hole is higher, ensure drain hose(s) are routed straight into the waste connection. - If the hole is through wood, make sure its edges are smooth and rounded. - If the hole is through metal, ensure you fit the supplied Edge Protector to prevent damage to the power cord. min. 7 7⁄8" (200 mm) 10 Water Connection Recommended HOT (Maximum 140°F/60°C). Supplied hose to suit 3⁄8" (9 mm) male compression fitting. Water Pressure Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) Models without water softener Max. 1 MPa (145 psi) Min. 0.03 MPa (4.3 psi)