Fisher and Paykel DD24STI7 BOOK INSTL DD24S PH7 US CA EN (English) - Page 15
Pull Through Hoses & Move Into The Cavity, Secure The Drawer, Integrated Only - Secure
View all Fisher and Paykel DD24STI7 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
14a PULL THROUGH HOSES & MOVE INTO THE CAVITY Vent Hose (Integrated models only) vent either through same cabinet or adjacent cabinet as per step 9a or 9b As you push product in, pull through hoses and cord, ensuring they don't get kinked or twisted. Important! If product cannot be pushed in far enough, pull out again and rearrange hoses and cord. Do not use excessive force, as doing so may squash the hoses and lead to incorrect operation. 16a INTEGRATED ONLY - SECURE THE EXTERNAL VENT 15a SECURE THE DRAWER Open the drawer halfway. Using a flat-bladed screwdriver, prize the gray rubber plug out of the trim moulding. 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. 15 1 Replace the gray rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 Repeat for all four brackets. 1 After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided. 2 Airflow