Fluke 287 Fluke 287 and 289 Multimeter Users Manual - Page 78
AC Voltage Specifications, Accuracy, Function, Range, Resolution, to 45 Hz, Hz to 10 kHz, to 20 kHz - specs
View all Fluke 287 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
287/289 Users Manual AC Voltage Specifications Function Range Resolution AC mV [5] AC V dBV Low pass filter [4] 50 mV [1] 500 mV 5 V [1] 50 V [1] 500 V [1] 1000 V -70 to -62 dB [3] -62 to -52 dB [3] -52 to -6 dB [3] -6 to +34 dB [3] 34 to 60 dB [3] 0.001 mV 0.01 mV 0.0001 V 0.001 V 0.01 V 0.1 V 0.01 dB 0.01 dB 0.01 dB 0.01 dB 0.01 dB 20 to 45 Hz 1.5 % + 60 1.5 % + 60 1.5 % + 60 1.5 % + 60 1.5 % + 60 1.5 % + 60 3 dB 1.5 dB 0.2 dB 0.2 dB 0.2 dB 2 % + 80 45 to 65 Hz 0.3 % + 25 0.3 % + 25 0.3 % + 25 0.3 % + 25 0.3 % + 25 0.3 % + 25 1.5 dB 1.0 dB 0.1 dB 0.1 dB 0.1 dB 2 % + 40 Accuracy 65 Hz to 10 kHz 0.4 % + 25 0.4 % + 25 0.6 % + 25 0.4 % + 25 0.4 % + 25 0.4 % + 25 2 dB 1 dB 0.1 dB 0.1 dB 0.1 dB 2 % +10 -6 % -60 [2] 10 to 20 kHz 0.7 % + 40 0.7 % + 40 1.5 % + 40 0.7 % + 40 Not Spec'd Not Spec'd 2 dB 1 dB 0.2 dB 0.2 dB Not Spec'd Not Spec'd 20 to 100 kHz 3.5 % + 40 [6] 3.5 % + 40 3.5 % + 40 [6] 3.5 % + 40 Not Spec'd Not Spec'd 3 dB 2 dB 0.8 dB 0.8 dB Not Spec'd Not Spec'd L [4] 1000 V 0.1 V 2 % + 80 2 % + 40 2 % + 40 [7] Not Spec'd Not Spec'd [1] Below 5 % of range, add 20 counts. [2] Specification increases linearly from -2 % at 200 Hz to -6 % at 440 Hz. Range is limited to 440 Hz. [3] dBm (600 Ω) is specified by adding +2.2 dB to the dBV range values. [4] 289 only. [5] 500 mV range specification between 64.000 kHz and 67.000 kHz is +(0.0 % to -5 % of reading); 50 mV range specification between 64.000 kHz and 67.000 kHz is +(0.0 % to -6 % of reading ±40 counts). Valid from -20 °C to 28 °C to +55 °C. [6] Add 2.5 % above 65 kHz. [7] Range is limited to 440 Hz. See Detailed Specifications introduction for additional information. 68