Fluke 54 FE 53 & 54 II Users Manual

Fluke 54 Manual

Fluke 54 manual content summary:

  • Fluke 54 | FE 53 & 54 II Users Manual - Page 1
    ® 53 & 54 Series II Thermometer Users Manual September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 2
    . Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, send your defective tester to the nearest Fluke Authorized Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 3
    Table of Contents Title Page Safety Information...1 Contacting Fluke ...1 Getting Started...4 Components...5 Display Elements ...6 Buttons...7 Using the Thermometer 9 Changing Setup Options 9 Entering and Exiting Setup 9 Changing the Logging Interval 10 Changing the Thermocouple Type
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 4
    53 & 54 Series II Users Manual Displaying Temperatures 14 Holding the Displayed Temperatures 14 Viewing the MIN, MAX, and AVG Readings 14 Using the Offset to Adjust for Probe Errors 15
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 5
    as specified in this manual. Otherwise, the protection provided by the meter may be impaired. Refer to safety information in Table 1 and the meter symbols in Table 2. Contacting Fluke To order accessories, receive assistance, or locate the nearest Fluke distributor or Service Center, call: 1-888
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 6
    53 & 54 Series II Users Manual Table 1. Safety Information WWarning A Warning identifies conditions the thermometer if it operates abnormally. Protection may be impaired. When in doubt, have the thermometer serviced. • Do not operate the thermometer around explosive gas, vapor, or dust. • Do not
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 7
    .) • Model 54: Measurement errors may occur if voltages on the measurement surfaces result in potentials greater than 1 V between the two thermocouples. When potential differences are anticipated between the thermocouples, use electrically insulated thermocouples. • When servicing the thermometer
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 8
    European Union directives. M Battery. Complies with relevant Canadian Standards Association directives. Getting Started Everything in this Users Manual applies both to Models 53 and 54 unless otherwise indicated. To become familiar with the thermometer, study the following: • Figure 1 and Table
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 9
    Components 3 4 5 6 7 xx 2 1 53 & 54 Series II Getting Started Table 3. Components A Thermocouple T1 input B Model 54: Thermocouple T2 input C Holster D Display E Buttons F Battery door G Batteries Figure 1. Components aat01f.eps 5
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 10
    53 & 54 Series II Users Manual Display Elements 2 3 45 1 xx 6 7 12 11 Figure 2. Display Elements 8 9 10 are displayed. G Low battery. Replace the batteries. H Primary Display. Model 53: T1 reading. Model 54: T1, T2, or T1-T2 reading. I The temperature units. J Secondary Display: MAX, MIN, AVG,
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 11
    53 & 54 Series II Getting Started Buttons Table 5. Buttons A Press A to turn the thermometer on or off. G (Shift function) Press G, M (CANCEL) to stop displaying the minimum, maximum,
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 12
    54 Series II Users Manual h T D K N E J r Table 5. Buttons (cont.) Press h to freeze or unfreeze the displayed readings. Press h when turning on the thermometer to test the display. All display elements appear. Model 54 to start or stop logging. During manual logging, the thermometer stores a
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 13
    settings. The thermometer stores the settings in its memory. Setup settings reset only when the batteries are removed for more than 2 minutes. 53 & 54 Series II Using the Thermometer Entering and Exiting Setup When the thermometer is in Setup mode, the display shows s. • Press D to start or
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 14
    53 & 54 Series II Users Manual Changing the Logging Interval The logging interval determines (2), 1 minute (3), 10 minutes (4), or user-defined (USef). You can also set the logging interval manually (0). Each time you press J, the thermometer stores the current readings in memory. 1. Press K or N
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 15
    the errors of a specific thermocouple. See "Using the Offset to Adjust for Probe Errors." The allowable adjustment range is ± 5.0 oC or K, and ± 9.0 oF. Model 54: You can store individual offsets for T1 and T2. 1. Press K or N until the display shows O and T1 or T2. 2. Press E to indicate that you
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 16
    53 & 54 Series II Users Manual Enabling or Disabling Sleep Mode The thermometer enters sleep mode if no button press occurs for 20 minutes. Pressing any button wakes the thermometer and
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 17
    as needed until the display shows 50 V or 60 V (50 Hz or 60 Hz). 4. Press E to store the line setting in memory. 53 & 54 Series II Measuring Temperatures Measuring Temperatures Connecting a Thermocouple Thermocouples are color coded by type based on the North American ANSI Color Code: Type Color
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 18
    Series II Users Manual Displaying Temperatures 1. Press C to select the correct temperature scale. 2. Hold or attach the thermocouple(s) to the measurement location. The temperature reading appears in the selected display. 3. Model 54: Press T to toggle between showing the T1, T2, and T1-T2 reading
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 19
    readings to stabilize. 4. In Setup change the offset until the primary display reading matches the calibration temperature. (See "Changing Setup Options.") 53 & 54 Series II Using Memory Using Memory During a logging session the thermometer stores logged readings in its memory. At the end of the
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 20
    53 & 54 Series II Users Manual Initial Conditions and Data Entries Logged readings include initial sets of temperature readings and 250 sets of initial conditions when logging individual points manually. Starting and Stopping Logging Setup, memory clear, and PC communications are inaccessible during
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 21
    or MIN MAX mode. • Press G, J (CLEAR MEMORY) to delete logged readings from memory. The display shows the following for 2 seconds. MEMORY cW f 53 & 54 Series II Using Memory Viewing Logged Readings 1. Press r to view logged readings. The display shows R. 2. Press K or N to scroll through the logged
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 22
    53 & 54 Series II Users Manual 3. Press M to step through the minimum, maximum, average, and current communication requires an IR (infrared) serial connection. Refer to the FlukeView Forms Installation Guide and FlukeView Help. FlukeView Forms places the logged readings into standard (default) or
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 23
    soft rag. 53 & 54 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you calibrate the thermometer, contact Fluke for the Service Center nearest you or follow the calibration procedure in the service manual listed in "
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 24
    53 & 54 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery Certification 3 AA batteries P, s Safety CSA C22.2 No. 1010.1 1992
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 25
    rbe-,eaKldoi-wn, gT−-+1, 00E0.-3,oaCoCn(d−(01N.45-t8yopFoFe)])::±a[0d.d050.%15o%f 54) of reading for J-, K-, E-, and N-type; and 0.45 % The above specifications do not include thermocouple error. 53 & 54 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory
  • Fluke 54 | FE 53 & 54 II Users Manual - Page 26
    53 & 54 Series II Users Manual 22
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

®
53 & 54 Series II
Thermometer
Users Manual
September 1999 Rev.1, 6/01
© 1999-2001 Fluke Corporation, All rights reserved. Printed in USA
All product names are trademarks of their respective companies.