Frigidaire FG4H2272UF Complete Owners Guide - Page 32

Concern, Potential Cause, Common Solution, Opening/Closing Of Doors/Drawers, Running of Refrigerator

Page 32 highlights

BEFORE CALLING Concern Potential Cause Common Solution Opening/Closing Of Doors/Drawers Door(s) will not close. • Door was closed too hard, • Close both doors gently. causing other door to open slightly. • Refrigerator is not level. It rocks on the floor when moved slightly. • Ensure floor is level and solid, and can adequately support the refrigerator. Contact a carpenter to correct a sagging or sloping floor. • Refrigerator is touching a wall or cabinet. • Ensure floor is level and solid, and can adequately support the refrigerator. Contact a carpenter to correct a sagging or sloping floor. • Food/packaging is obstructing the door from closing. • Make sure there is no food/packaging blocking the doorway. Drawers are difficult to move. • Flipper mullion on left fresh • Ensure the flipper mullion is in the food door is not in the correct position to allow the door to correct position. close. (See Flipper Mullion section.) • Food is touching shelf on top of drawer. • Remove top layer of items in drawer. • Track that drawers slide on • Ensure drawer is properly installed on is dirty. track. Running of Refrigerator Compressor • Refrigerator is in defrost does not run. cycle. • Plug at electrical outlet is disconnected. • Clean drawer, rollers, and track. See Care & Cleaning. • This is normal for a fully automatic defrost refrigerator. The defrost cycle occurs periodically, lasting about 30 minutes. • Ensure plug is tightly pushed into outlet. • House fuse blown or tripped circuit breaker. • • Power outage. • Refrigerator • The variable speed • seems to run compressor is designed too much or to run 100% of the time too long. except during the defrost cycle. At times it will run faster, such as after a defrost cycle. Digital Temperature Setting Display Digital temperature displays an error. • Electronic control system • has detected a performance problem. Check/replace fuse with a 15 amp timedelay fuse. Reset circuit breaker. Check house lights. Call local electric company. It is normal for the compressor to run continuously except during defrost mode. Contact Electrolux Customer Care for assistance with any errors or codes flashing in the display by calling 1-800-374-4432. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

32
BEFORE CALLING
Concern
Potential Cause
Common Solution
Opening/Closing Of Doors/Drawers
Door(s) will
not close.
Door was closed too hard,
causing other door to open
slightly.
Refrigerator is not level.
It rocks on the floor when
moved slightly.
Refrigerator is touching a
wall or cabinet.
Food/packaging is
obstructing the door from
closing.
Flipper mullion on left fresh
food door is not in the
correct position.
Close both doors gently.
Ensure floor is level and solid, and can
adequately support the refrigerator.
Contact a carpenter to correct a sagging
or sloping floor.
Ensure floor is level and solid, and can
adequately support the refrigerator.
Contact a carpenter to correct a sagging
or sloping floor.
Make sure there is no food/packaging
blocking the doorway.
Ensure the flipper mullion is in the
correct position to allow the door to
close. (See Flipper Mullion section.)
Drawers are
difficult to
move.
Food is touching shelf on
top of drawer.
Track that drawers slide on
is dirty.
Remove top layer of items in drawer.
Ensure drawer is properly installed on
track.
Clean drawer, rollers, and track. See
Care & Cleaning.
Running of Refrigerator
Compressor
does not run.
Refrigerator is in defrost
cycle.
Plug at electrical outlet is
disconnected.
House fuse blown or
tripped circuit breaker.
Power outage.
This is normal for a fully automatic
defrost refrigerator. The defrost cycle
occurs periodically, lasting about 30
minutes.
Ensure plug is tightly pushed into outlet.
Check/replace fuse with a 15 amp time-
delay fuse. Reset circuit breaker.
Check house lights. Call local electric
company.
Refrigerator
seems to run
too much or
too long.
The variable speed
compressor is designed
to run 100% of the time
except during the defrost
cycle. At times it will run
faster, such as after a
defrost cycle.
It is normal for the compressor to run
continuously except during defrost
mode.
Digital Temperature Setting Display
Digital
temperature
displays an
error.
Electronic control system
has detected a performance
problem.
Contact Electrolux Customer Care for
assistance with any errors or codes
flashing in the display by calling
1-800-374-4432.