Frigidaire FH36DD50MS Use and Care Manual - Page 8

Plan the Electrical Connection

Page 8 highlights

PLANNING Plan the Electrical Connection The downdraft blower system draws 2.8 AMPS and requires a 120 VAC, 60 Hz circuit. The unit has a 28 inches long power cord with a 3 pronged plug. Plan to provide a grounded outlet in a location which will allow the unit's power cord to reach.  NOTE If the 30" model is being installed in a 30" wide cabinet or the 36" model in a 36" wide cabinet, the outlet cannot be located on the back wall of cabinet. Outlet may also be wall-mounted with access hole in cabinet. M M 9-1/2" (24.1cm) 23-3/4" (60.3 cm) 22-1/8" (56.2 cm) 19-1/16" (48.4 cm) 4-5/8" (11.8 cm) 14-3/4" (37.5 cm) 8-3/4" (22.2 cm) 7-7/8" (20 cm) 6-1/2" (16.5 cm) Recommended Electrical Outlet Locations (All Shaded Areas) Electrical Outlet Location Model M - From Center FH30DD50MS 13 ½" (34.3 cm) FH36DD50MS 16 ½" (42.0 cm) All vertical dimensions relative to top surface of the countertop. All horizontal dimensions relative to cutout in the countertop. Ensure that access to the electrical outlet will not be blocked by the ducting after installation. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

8
Plan the Electrical Connection
The downdraft blower system draws 2.8 AMPS and requires
a 120 VAC, 60 Hz circuit.
The unit has a 28 inches long power cord with a 3 pronged
plug. Plan to provide a grounded outlet in a location which
will allow the unit’s power cord to reach.
PLANNING
NOTE
If the 30” model is being installed in a 30” wide cabinet
or the 36” model in a 36” wide cabinet, the outlet cannot
be located on the back wall of cabinet.
Outlet may also be wall-mounted with access hole in
cabinet.
Recommended Electrical
Outlet Locations
(All Shaded Areas)
All vertical dimensions relative to
top surface
of the countertop.
All horizontal dimensions relative to
cutout
in the countertop.
Ensure that access to the electrical outlet will not be blocked by
the ducting after installation.
Electrical Outlet Location
Model
M - From Center
FH30DD50MS
13 ½” (34.3 cm)
FH36DD50MS
16 ½” (42.0 cm)
7-7/8”
(20 cm)
8-3/4”
(22.2 cm)
M
M
6-1/2”
(16.5 cm)
19-1/16”
(48.4 cm)
23-3/4”
(60.3 cm)
4-5/8"
(11.8 cm)
9-1/2"
(24.1cm)
14-3/4"
(37.5 cm)
22-1/8"
(56.2 cm)