Fujitsu MJA2500BH Maintenance Manual - Page 152
Table 5.27, WRITE SAME 2/2, ERROR RECOVERY CONTROL, Return Current Value
View all Fujitsu MJA2500BH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Interface Table 5.27 WRITE SAME (2/2) Byte(hex) 0C to13 14 to17 18 to 1FF Name Count Pattern (Reserved) Value Description (8 byte) Number of Sectors (4 byte) If the Function Code is 0001h, this field contains a 32-bit pattern that is written on the media. - Reserved * It is invalid excluding the description value. Table 5.28 ERROR RECOVERY CONTROL Byte(hex) Name Value Description 00, 01 02, 03 04, 05 06, 07 08 to 1FF Action Code 0003h ERROR RECOVERY CONTROL Function Code 0001h 0002h Set New Value The retry processing when making an error in the specified timer Return Current Value The timer value of the error recovery being set now is displayed in SN /SC field. Selection Code 0001h Read Timer 0002h Write Timer Set to Timer Value (x 100 ms) Value (2 byte) Minimum value is 5 sec. (ex.) 0000h: Disable timeout 0031h: Invalid 0032h: 5000 ms (5 s) (Reserved) - Reserved * It is invalid excluding the description value. 5-78 C141-E293