Garmin Edge 800 Edge 800 Quick Start Guide - Page 10
the first 60 passes after a reset.
View all Garmin Edge 800 Edge 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
The spoke magnet can face away from the GSC 10 if there is not enough room between the sensor arm and the spoke. The spoke magnet must line up with the indication line ➑ on the sensor arm. 6. Loosen the screw ➒ on the sensor arm. 7. Move the sensor arm to within 5 mm of the spoke magnet. You can also tilt the GSC 10 closer to either magnet for improved alignment. 8. Press the Reset key ➓ on the GSC 10. The LED turns red, then green. 9. Pedal to test the sensor alignment. The red LED blinks each time the pedal magnet passes the sensor. The green LED blinks each time the spoke magnet passes the sensor arm. note: The LED blinks for the first 60 passes after a reset. Press Reset again if you require additional passes. 10. When everything is aligned and working correctly, tighten the cable ties, the sensor arm, and the spoke magnet. Garmin recommends that the torque is 1.9 to 2.4 lbf-in to ensure a water tight seal on the GSC 10 sensor arm. When the GSC 10 is paired, a message appears, and appear solid on the status page. 8 Edge 800 Quick Start Manual