GE AJCS12DCB Owners Manual - Page 6

About the controlson the air conditionermmodels with touchpads.

Page 6 highlights

About the controlson the air conditionermmodels with touchpads. Auxiliary Controls- TemperatureLimiting To reach the auxiliary controls remove the fl'ont g_ille. Access them through the small rectangular opening above the control panel. Temperature limiting can reduce energy costs b)' limiting the lowest temperattu'e that can be set fin" cooling, Temperattu'e limiting is controlled by switches 1-3 of au_lia_a' controls. TL1(C){TempL. imit1 Cool) TL2(C){TempL. imit2 Cool) TL3(C/(TempL. imit3 Cool/ -- UP Nofunctioll(reserved for futureuse) DOWN Temperature limiting during COOLmode (all temperatures shown in °F) UP DOWN Minimum Maximum NONE 1, 2, 3 60° 85° 1 2,3 64° 85° 1, 2 3 66° 85° 2 1,3 68° 85° 2,3 1 70° 85° 1, 2, 3 NONE 72° 85° 1,3 2 74° 85° 3 1, 2 76° 85°

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

About the controlson the air conditionermmodels with touchpads.
Auxiliary Controls- TemperatureLimiting
To
reach
the
auxiliary
controls
remove
the
fl'ont
g_ille.
Access
them
through
the
small
rectangular
opening
above
the
control
panel.
Temperature
limiting
can
reduce
energy
costs
b)'
limiting
the
lowest
temperattu'e
that
can
be
set
fin" cooling,
Temperattu'e
limiting
is
controlled
by
switches
1-3
of
au_lia_a'
controls.
TL1(C){Temp.
Limit1
Cool)
TL2(C){Temp.
Limit2
Cool)
TL3(C/(Temp.
Limit3
Cool/
UP
--
Nofunctioll(reserved
for futureuse)
DOWN
Temperaturelimiting during COOLmode
(all temperatures shown in °F)
UP
DOWN
Minimum
Maximum
NONE
1, 2, 3
60°
85°
1
2,3
64°
85°
1, 2
3
66°
85°
2
1,3
68°
85°
2,3
1
70°
85°
1, 2, 3
NONE
72°
85°
1,3
2
74°
85°
3
1, 2
76°
85°